摘要 为解决絮凝沉淀法去除饮料厂废水氨氮测试用水样中的悬浮物效果差的问题对调整和絮凝剂加入量做了研究实验,提升了絮凝效果,悬浮物去除率可达到99.17%,将此方法与预蒸馏法对比,操作简便且样品氨氮测定结果更加准确。 This paper is prepared to solve the problem of incomplete removal of suspended solids in beverage factory wastewater by flocculation precipitation. The research on pH adjustment and flocculant addition amount has been carried out to improve the flocculation effect, and the suspension removal rate can reach 99.17%. This method is easier and more accurate than the pre-distillation method.
作者 黄叶飞 邵增琅 裴少芬 王晓霞 黄鸣 唐杏燕 HUANG Ye-fei;SHAO Zeng-lang;PEI Shao-fen;WANG Xiao-xia;HUANG Ming;TANG Xing-yan(Nanjing Rongdian Food Technology Co,, Ltd,, Nanjing 211300, China)
出处 《饮料工业》 2019年第2期64-66,共3页 Beverage Industry
基金 江苏省重点研发计划(现代农业)项目(BE2017357-2)
关键词 饮料厂废水 氨氮 絮凝沉淀 pH 悬浮物含量 beverage factory wastewater ammonia nitrogen flocculation precipitation pH suspended solids content