期刊文献+

某乡镇垃圾回收站冬季环卫作业细菌污染情况抽样调查 被引量:2

Sampling survey of bacterial contamination of winter sanitation work in township garbage collection stations
原文传递
导出
摘要 目的分析东莞市塘厦镇中型垃圾回收站冬季细菌污染情况。方法以东莞市塘厦镇数量居多的中型垃圾回收站为研究对象,以细菌总数、大肠菌群、沙门氏菌的检测为卫生学指标,采用多阶段随机抽样选取研究站点;以入选站点全体工人为研究人群,检测工人手掌、清洁工具和运输车辆的手掌握持部件表面污染程度,同时检验站内空气及垃圾渗漏液,分析受污染情况。结果 3家中型垃圾回收站纳入研究范围,对站内物体表面、环卫作业人员手部、回收站空气检测均未发现大肠菌群和沙门氏菌。对站内物体表面检测,电动车垃圾桶检出细菌总数最多为5 cfu/cm^2;环卫作业人员手部洗手后细菌总数最高值为9 cfu/cm^2,而未洗手前检出细菌总数为250 cfu/cm^2。对3个垃圾站点站内值班房、垃圾压缩机、站内工具存放间空气进行检查,发现3个站点中垃圾压缩机中细菌总数污染最严重,A站点15 cfu/cm^2,B站点17 cfu/cm^2,C站点13 cfu/cm^2。垃圾渗漏液细菌总数均高达1 000 cfu/mL。且检出大肠菌群、沙门氏菌及霉菌。结论冬季环卫作业细菌污染防护重点应在环卫工人手部,并对垃圾渗漏液进行及时处理,降低感染风险。 Objective To analyze the bacterial contamination level of medium-sized garbage collection stations in Tangxia Town of Dongguan City in winter.Methods The count of total bacteria, coliform bacteria, Salmonella and other pathogenic bacteria were selected as major indexes, and the multistage random sampling was used to select the research sites. All the workers in the selected sites were taken as the research population, and the contamination degrees of handholding parts of workers’ palms, cleaning tools and transport vehicles were detected. At the same time, the air and garbage leachate were checked in the station, and the pollution level was analyzed.Results Three medium-sized garbage recycling stations were included in the study. No coliform bacteria and Salmonella were detected on the hand-holding parts, hands of sanitation workers, and the air of the recycling stations. On the surface of objects, the maximum count of bacteria detected in electric vehicle garbage was 5 cfu/cm^2;the maximum count of bacteria detected on sanitation workers’ hands after washing was 9 cfu/cm^2, while the maximum count of bacteria detected before washing was 250 cfu/cm^2. The air pollution of duty rooms, waste compressors and tool storage rooms in the three garbage stations was examined, it was found that the most serious pollution of garbage compressor was 15 cfu/cm^2 in Station A, 17 cfu/cm^2 in Station B, and 13 cfu/cm^2 in Station C.The total number of bacteria in landfill leachate was up to 1 000 cfu/ml, and coliforms, Salmonella and mould were also found.Conclusion The total bacterial count of sanitation workers before hand-washing exceed the limit in winter, and the total bacterial count of waste compressor is the highest in work sites. Therefore, the prevention of bacterial contamination in winter sanitation work should be focus on the hand disinfection of sanitation workers, and disposal of landfill leachate, so as to reduce the risk of infection.
作者 黄晋 李荣宗 罗彩凤 HUANG Jin;LI Rong-zong;LUO Cai-feng(Tangxia Town Center for Disease Control and Prevention, Dongguan 523710, China)
出处 《中国校医》 2019年第5期323-324,339,共3页 Chinese Journal of School Doctor
基金 东莞市社会科技发展项目(2017507150105337) 广东省医学科研基金项目(B2014015)
关键词 垃圾处理 回收 季节/冬 细菌污染 手表面 用具 garbage disposal recycle season/winter bacterial pollution suffice of hand tool
  • 相关文献

参考文献7

二级参考文献134

共引文献201

同被引文献16

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部