摘要 柴油发电机组的热管理系统属于数据中心(IDC)机房能耗管理系统的创新型设计,是针对极寒环境气候条件下机组运行而进行的设计,通过控制机组散热风扇的转速控制机房进风量,调节机房的温度,使柴油机能够始终保持在最适宜温度的工作环境下,使燃油燃烧得更加充分,有明显的节能减排效果。 Thermal energy management system of IDC diesel generator is a new creative design for energy consumption management system of IDC buildings,which is for the diesel generator better running in frigid area. The system can adjust the temperature of the set room by controlling the running speed of the fan to control the inlet wind so to keep the diesel generator working in the adaptable temperature environment with full combustion and high energy-saving and emission-reduction.
作者 杨少慰 许乃强 田智会 YANG Shao-wei;XU Nai-qiang;TIAN Zhi-hui(Shanghai COOLTECH Power Co.,Ltd.,Shanghai 201712,China)
出处 《机电工程技术》 2019年第5期151-154,共4页 Mechanical & Electrical Engineering Technology
关键词 柴油发电机组 硅油离合器 节能 diesel generator silicon oil clutch energy-saving