摘要 原煤仓分炉煤计量是火力发电企业入炉煤耗数据来源的关键环节,原煤仓分炉煤计量装置因称量量程大而采用传统的标准砝码测量法很难进行量值溯源,本文采用基于标准载荷测量法对原煤仓分炉煤计量装置计量特性进行测量,并对测量过程产生的不确定度来源进行定性分析和定量计算。实验和计算数据表明,应用标准负荷传感器和高稳定性力源控制系统等组成标准载荷测量装置对原煤仓分炉煤计量系统进行量值溯源,其计量特性数据是可靠的。 The measurement of raw coal bunker sub-furnace coal is the key link of coal consumption data source for thermal power enterprises. Because of the large scale of measurement, it is difficult to trace the measurement value by traditional standard weight measurement method. In this paper, the measurement characteristics of raw coal bunker sub-furnace coal measurement device are measured by standard load measurement method, and the uncertainty caused by the measurement process is analyzed. Qualitative analysis and quantitative calculation are carried out. The experimental and computational data show that the standard load measuring device composed of standard load sensor and high stability power source control system is used to trace the quantity value of the coal metering system of the original coal bunker furnace, and its metering characteristic data is reliable.
作者 阮光 杨凯 周洪元 沈博宇 RUAN Guang
出处 《衡器》 2019年第5期12-16,共5页 Weighing Instrument
基金 浙江省能源集团科技项目(项目编号:ZN-KJ-2017-021 项目名称:基于动态修正的分炉煤计量系统的研究与开发)的支持
关键词 分炉煤计量 标准载荷测量装置 校准方法 不确定度分析与评定 coal metering for separate boilers standard load measuring device calibration method uncertainty analysis and evaluation
  • 相关文献

参考文献3

二级参考文献2

  • 1美国莫迪康公司.MODICON984可编程序控制器系统手册[M].,1993..
  • 2美国莫迪康公司.MODICON984可编程序控制器软件手册[M].,1993..

共引文献6

同被引文献3

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部