期刊文献+

Mass attenuation coefficient of olive peat material for absorbing gamma ray energy 被引量:1

Mass attenuation coefficient of olive peat material for absorbing gamma ray energy
下载PDF
导出
摘要 The mass attenuation coefficients (l/q) of a natural material, i.e., olive peat, were measured at photon energies of 0.059, 0.356, 0.662, 1.17, and 1.332 MeV and compared with those of concrete and Pb. The experimental samples were irradiated with 214Am, 133Ba, 137Cs, and 60Co point sources using a transmission arrangement. The olive peat samples were obtained from different areas in Jordan, namely Mafraq (sample M), Kerak (sample K), Ajloun (sample A), and Irbid (sample I), and photon energies were measured using a NaI(Tl) scintillation detector with an energy resolution of 7.6% at 662 keV. The differences in the l/q of olive peat samples and the calculated l/q of concrete were consistently within 0.7% at photon energies of 0.356–1.332 MeV. This finding indicates that olive peat can be used in radiation applications in the field of medical physics. Finally, the half-value layer (HVL) of the experimental samples was measured, and results were compared with those of concrete and Pb. Pb and concrete exhibited minimal HVL values due to their high density, and the HVL of olive peat revealed lower shielding effectiveness than that of concrete. The mass attenuation coefficients(μ/ρ)of a natural material,i.e.,olive peat,were measured at photon energies of 0.059,0.356,0.662,1.17,and 1.332 MeV and compared with those of concrete and Pb.The experimental samples were irradiated with 214Am,133Ba,137Cs,and 60Co point sources using a transmission arrangement.The olive peat samples were obtained from different areas in Jordan,namely Mafraq(sample M),Kerak(sample K),Ajloun(sample A),and Irbid(sample I),and photon energies were measured using a NaI(T1)scintillation detector with an energy resolution of 7.6% at 662 keV.The differences in the μ/ρ of olive peat samples and the calculated μ/ρ of concrete were consistently within 0.7% at photon energies of 0.356-1.332 MeV.This finding indicates that olive peat can be used in radiation applications in the field of medical physics.Finally,the half-value layer(HVL)of the experimental samples was measured,and results were compared with those of concrete and Pb.Pb and concrete exhibited minimal HVL values due to their high density,and the HVL of olive peat revealed lower shielding effectiveness than that of concrete.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第7期27-35,共9页 核技术(英文)
关键词 OLIVE PEAT ATTENUATION COEFFICIENT Halfvalue layer GAMMA RAY Olive peat Attenuation coefficient Halfvalue layer Gamma ray
  • 相关文献

共引文献5

同被引文献14

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部