期刊文献+

Pt-TiO2/Ti电催化氧化有机废水的研究

Study on Electrocatalytic Oxidation of Organic Wastewater with DSA Anode
下载PDF
导出
摘要 根据氟碳化工行业生产、生活废水的产生特点,针对公司环保站废水经物化、生化处理后的氨氮、COD仍较高的水质特征;用DSA(DimensionStableAnode)形稳阳极对有机废水进行了催化降解研究,经实验表明:Pt-TiO2/Ti电极对废水有较好的催化降解效果,在电流密度200A/m^2电解60min后,进水的COD与氨氮分别从2480mg/L、55mg/L(均值)稳定降到400mg/L、8.0mg/L以下,实现了其同步、稳定、高效去除。同时提高了废水可生化性,此项研究也为该技术工程化应用提供一定参考。 According to the characteristics of production and domestic wastewater in fluorocarbon chemical industry, coping with the water quality characteristics of wastewater treatment station after physicochemical and biochemical treatment, the catalytic degradation of organic wastewater was studied with DSA (Dimension Stable Anode) stable anodes. The experimental results show that the electrode has good catalytic degradation effect on wastewater in experiments. The results showed that after electrolysis of 60 min by current density 200 A/m2,The influent COD and NH3-N dropped steadily from 2480 mg/L ,55 mg/L to below 300 mg/L, 5.0 mg/L, respectively. Its synchronization, stability and efficient removal are realized. At the same time, it not only enhanced the biodegradability of wastewater,but also provides some references for the engineering application of the technology.
作者 彭旭 杨宏波 裘群国 潘柯君 夏帅 周玲 PENG Xu;YANG Hong-bo;QIU Qun-guo;PAN Ke-jun;XIA Shuai;ZHOU Ling(Zhejiang Lantian Enviromental Protection Hi-Tech Co, Ltd.,Hangzhou ,Zhejiang 310018, China;Sinochem Lantian Co., Ltd. ,Hangzhou, Zhejiang 310051, China)
出处 《浙江化工》 CAS 2019年第6期29-32,共4页 Zhejiang Chemical Industry
关键词 电催化氧化 氨氮 COD 工业废水 Pt-TiO2/Ti DSA形稳阳极 electrocatalytic oxidation NH3-N COD Industrial wastewater Pt-TiO2/Ti, dimension stable anode
  • 相关文献

参考文献8

二级参考文献81

共引文献141

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部