氢氧化钠标准溶液浓度的不确定度评估

The Evaluation of Uncertainty of Sodium Hydroxide
下载PDF
导出
摘要 研究氢氧化钠标准溶液浓度标定过程中的不确定度,通过数学模型评估不确定分量。结果表明:氢氧化钠标准溶液浓度的相对扩展不确定度为0.5076±0.0009mol/L(k=2);氢氧化钠标准溶液所消耗体积的不确定度影响最大。 The uncertain in the calibration process of sodium hydroxide standard solution concentration was studied and uncertainty components were evaluated by mathematical models.The results showed:the relative expanded uncertainty of sodium hydroxide stangard solution concentration was 0.5076±0.0009 mol/L(k=2).The uncertainty of the volume of sodium hydroxide standard solution was the largest influence.
作者 闫建康 张桂荣 王红宁 YAN Jian-kang;ZHANG Gui-rong;WANG Hong-ning(Shanxi Institute of Industrial Standardization,Taiyuan 030000,China;Shanxi Liangfen Vinegture Co. Ltd.,Taiyuan 030032,China;Shanxi Acsdemy of Agricultural Sciences Pomolpgy Institute ,Taiyuan 030031,China)
出处 《信阳农林学院学报》 2019年第2期108-110,共3页 Journal of Xinyang Agriculture and Forestry University
关键词 氢氧化钠 不确定度 评定 标准溶液 sodium hydroxide uncertainty evaluation standard solution