期刊文献+

某垃圾池底基础承台混凝土水化热温度变化 被引量:2

Research on Temperature Change of Hydration Heat in Mass Concrete Foundation Pedestal
下载PDF
导出
摘要 研究了基础承台混凝土浇筑凝结过程中温度变化趋势。采用温度计定时对某垃圾池底基础承台上中下三层从浇筑开始进行温度监控,得出温度变化规律并绘制对应的趋势图。研究表明:垃圾池基础承台的水化热温度随混凝土龄期发展经历3个阶段:即上升阶段、稳定阶段和下降阶段。并且上层温度下降最快,底层温度下降最慢,温控措施的重点应放在承台下部。为以后类似的结构采取措施降低水化热温度提供参考。 The temperature variation trend during the concrete pouring and setting process of foundation cap was studied.Thermometers was used to monitor the temperature of the upper, middle and lower floors of the foundation cap of a garbage pool from the beginning of pouring.The research shows that the temperature of hydration heat of the foundation cap of the garbage can goes through three stages with the development of concrete age: rising stage, stable stage and falling stage. In addition,the temperature of the upper layer drops the fastest, and that of the bottom layer drops the slowest. It provides a reference for similar structures to take measures to reduce the temperature of hydration heat.
作者 韩彰 HAN Zhang(Department of Architectural Engineering, Anhui Communications Vocational & Technical College, Anhui Hefei 230051, China;School of Engineering Science, University of Science and Technology of China, Anhui Hefei 230026, China)
出处 《华北理工大学学报(自然科学版)》 CAS 2019年第3期90-94,101,共6页 Journal of North China University of Science and Technology:Natural Science Edition
基金 安徽省高校拔尖人才培育资助项目(gxgnfx2018136)
关键词 混凝土 水化热 温升 控制措施 concrete hydration heat temperature rise control measure