摘要
应用ATG-6118H痕量氢在线自动分析仪在水井类观测点观测过程中发现,外界观测环境的变化对于痕量氢浓度的观测存在一定干扰。文章依据宁河痕量氢观测井的观测环境及供电系统的改造过程,对2017年11月11日井房改造完成前后的痕量氢浓度数据进行分析论述,为该仪器的后续观测提供一些借鉴经验。
During the observation of the trace-hydrogen concentration in water wells by the ATG-6118H online automatic trace-hydrogen analyzer,it was found that changes in the external observational environment had some interference to the observation of trace-hydrogen concentration.Based on the observational environment of the Ninghe trace-hydrogen observation well and the renovation process of power supply system,the data of trace-hydrogen concentration before and after the completion of the renovation of the well house on November 11,2017 were analyzed and discussed.Our results provide some experience for the follow-up observation of the instrument.
作者
东得淼
谷茂龙
李恩建
孙嘉良
冯克存
DONG De-miao;GU Mao-long;LI En-jian;SUN Jia-liang;FENG Ke-cun(Earthquake Administration of Tianjing,Tianjin 300191,China)
出处
《山西地震》
2019年第2期29-32,共4页
Earthquake Research in Shanxi
基金
中国地震局“监测、预报、科研”三结合课题(170301)
关键词
痕量氢
外墙保温
供电系统
Trace hydrogen
External wall insulation
Power supply system