期刊文献+

采集站(FDU)壳体螺丝孔滑扣的修复

Repair of the screw hole of the field digital unit (FDU) housing
下载PDF
导出
摘要 随着国家对天然气勘探力度的加大,布设的任务越来越多,项目生产的节奏也越来越快。高的生产时效,对设备投入的数量、质量都有很高的要求。要保证设备投入的数量、质量就必须缩短设备维修周期,减少设备故障率。本文就设备故障中的采集站进水原因进行了详细的分析,提出了解决问题的具体方法,得出了使用效果比较良好的结论,为物探生产节省了成本。 With the intensification of national natural gas exploration, more and more tasks are laid out, and the rhythm of project production is also faster and faster. High production efficiency requires high quantity and quality of equipment input. To ensure the quantity and quality of equipment input, it is necessary to shorten the equipment maintenance cycle and reduce the equipment failure rate. This paper makes a detailed analysis of the causes of the water inflow from the acquisition station in the equipment failure, puts forward specific methods to solve the problem, and draws a conclusion that the application effect is better, which saves the cost for geophysical prospecting production.
作者 叶苇 杨森 覃建 胡克 况伟 Ye Wei;Yang Sen;Qin Jian;Hu Ke;Kuang Wei
出处 《物探装备》 2019年第2期107-109,共3页 Equipment for Geophysical Prospecting
关键词 FDU 螺丝滑扣 采集站 壳体 维修方法 FDU screw slip acquisition station case maintenance method
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部