期刊文献+

窄脉冲阵列激光器峰值功率测试的研究 被引量:6

Study on the technique for measuring the peak power of narrow pulsed semiconductor laser arrays
下载PDF
导出
摘要 窄脉冲半导体激光器阵列输出的峰值功率必须准确测量,测量精度直接关系到光电系统的质量。本文介绍一种基于对数放大技术和8051F020单片机,采用脉冲展宽和峰值保持原理,通过快速放电复零从而直接测量窄脉冲阵列半导体激光器峰值功率的方法。测试结果表明,标定误差小于3%,测量准确度高,重复测量误差都在±1.7%之内。该测量方法研制的仪器具备便携、测试速度快、成本低的特点,并具有波形输出接口,适合空间有限的快速检测需求。 The peak power of narrow pulsed semiconductor laser arrays should be measured accurately,and the measurement accuracy is directly related to the quality of photoelectric system.In this paper,a measurement technique for measuring the peak power of narrow pulsed semiconductor laser arrays is proposed.The technique collect the data by logarithmic amplification technology and 8051F020 single chip microcomputer.The peak power is measured directly by broadening pulse width,holding peak and resetting with discharging rapidly.The test results show that the calibration error is less than 3%,the measurement accuracy is high,and the repeated measurement error is within 1.7%.The instrument developed by this method has the characteristics of portability,fast test speed and low cost,and has waveform output interface,which is suitable for the rapid test with limited space.
作者 胡峥 邵莉芬 李川 金张 HU Zheng;SHAO Li-fen;LI Chuan;JIN Zhang(Wuhan Instrument Electronics School,Wuhan 430205,China;Wuhan U.Creative Information Technology Co.,Ltd.,Wuhan 430205,China)
出处 《激光与红外》 CAS CSCD 北大核心 2019年第6期670-674,共5页 Laser & Infrared
基金 湖北名师工作室项目资助
关键词 半导体激光器阵列 峰值功率 窄脉冲 峰值保持 对数放大 semiconductor laser arrays peak power narrow pulsed peak holding logarithmic amplification
  • 相关文献

参考文献7

二级参考文献31

共引文献37

同被引文献55

引证文献6

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部