摘要
目前地暖技术在居住建筑中趋于成熟,但公建中,因其变化多样的建筑造型和丰富的建筑功能,其地暖设计在系统形式、配管间距、盘管布置和热计量方面都有许多不同之处。结合几年来在公建中的设计经验,以应县四通物流综合楼为例,总结、介绍了公共建筑中低温热水地板辐射供暖系统的设计。
At present, the floor heating technology is mature in residential buildings, but in public buildings, because of the variety of architectural modeling and rich architectural function, the design of floor heating have many differences in the system form, pipe spacing, coil pipe layout and heat metering. Combining with the design experience in the public buildings in recent years, taking Sitong logistics comprehensive building of Yingxian for example, this paper summarized and introduced the design of low temperature hot water floor radiant heating system in public buildings.
作者
李静玮
LI Jingwei(CNNC Xinneng Nuclear Engineering Co., Ltd., Taiyuan 030012, Shanxi, China)
出处
《能源与节能》
2019年第6期47-49,共3页
Energy and Energy Conservation
关键词
公共建筑
低温热水地板辐射供暖
供暖系统设计
public buildings
low temperature hot water floor radiant heating
design of heating system