文中阐述了某石化公司的空分冷箱运行年限超期、内部保冷效果下降的实际现状。分析了冷箱保冷材料干燥度的影响因素,更新改造了装置的密封气供应系统的安装布局,并利用装置大检修时机实现了该冷箱密封气供应系统的升级优化。
This paper expounded the current situation of the air separation cold box with exceeding the operation deadline and de. clining of internal cold insulation effect in a petrochemical company,analyzed factors affecting the dryness of cold box insulation ma. terials, updated and reformed the installation layout of the sealed gas supply system, and realized the upgrading and optimization of the sealed gas supply system of the cold box by taking advantage of the opportunity of overhaul of the unit.