期刊文献+

层流手术室预防手术切口感染的效果 被引量:2

下载PDF
导出
摘要 目的探讨层流手术室对手术切口感染的预防效果。方法选择在手术室行普通手术的124例患者为研究对象。采用随机数字表法将其分为对照组和观察组,每组各62例。对照组分别于普通手术室、层流手术室进行手术。比较2组手术切口感染率,并对普通和层流手术室内菌落进行采样,比较其空气含菌量。结果对照组手术切口感染率为12.90%,高于观察组的1.61%(P<0.05);术前10min普通和层流手术室空气含菌量比较差异无统计学意义(P>0.05),术后10min普通和层流手术室空气含菌量均高于术前10min(P<0.05),且普通手术室空气含菌量高于层流手术室(P<0.05)。结论层流手术室在手术切口感染预防中能够明显降低感染发生率,有助于控制医院感染的发生。
作者 肖越
出处 《实用临床医学(江西)》 CAS 2019年第4期98-99,共2页 Practical Clinical Medicine
  • 相关文献

参考文献5

二级参考文献39

  • 1傅小芳,刘金妹,顾崎,沈瑞红.普通手术室和层流洁净手术室对手术切口感染率的影响[J].中国感染控制杂志,2007,6(1):24-26. 被引量:36
  • 2Lidwell OM,Lowbury EJL,Wlyte W,et al.Airborne contamination of wounds in Joint replacement operations:the relationship to sepsis rates[J].Journal of Hospital Infection,1983,4(2):111-131.
  • 3Kirkland KB,Briggs JP,Trivette SL,et al.The impact of surgical site infections in the 1990s:attributable mortality,excess length of hospitalization,and extra costs[J].Infect Control Hosp Epidemiol,1999,20(11):725-730.
  • 4Whyte W,Hodgson R,Tinkler J.The importance of airborne bacterial contamination of wounds[J].J Hosp Infect,1882,3:123-135.
  • 5Clarke MT,Lee PT,Roherts CP,et al.Contamination of primary total hip replacements in standard and ultraclean operating theaters detected by the polymerase chain reaction[J].Acta Orthop Scand,2004,75:544-548.
  • 6Gastmeier P,Breier A,Brandt C.Influence of Laminar airflow on prosthetic joint infections:a systematic review[J].Journal of Hospital Infection,2012,81:73-78.
  • 7Hooper G,Roth well A,Frampton C,et al.Does the use of laminar airflow and space suits reduce early deep infection after total hip and knee replacement[J].J Bone Joint Surg,2011,93-8:85-90
  • 8Brand C,Hott U,Sohr D,et al.Operating room ventilation with laminar airflow shows no protective effect on the surgical site infection rate in orthopedic and abdominal surgery[J].Ann Surg,2008,348:695-700.
  • 9Robert-Koch-Instut,Prvention postoperativer Infektionen im Operationsgebiet[M].Bundesgesund heitsblatt,2007,50:16.
  • 10Cacciari P,Giannoni R,Marcelli E,et al.Cost evaluation of a ventilation system for operating theatre:an ultraclean design versus a conventional one[J].Ann Ig 2004,16:803-809.