文章介绍了新型自动气象站的信号传输方式和接线图,针对昌乐自动气象站遭受雷击出现的综合故障,按图进行检修,快速找到发生故障的位置并修复。同时探讨了降低自动气象站因雷击造成损失的方法。为台站业务人员排除和检修故障提供参考。
This paper introduces the signal transmission modes and wiring diagrams of new automatic weather station.Aiming at the integrated faults caused by lightning strike in Changle automatic weather station,the faults are quickly found and repaired according to the diagrams.Meanwhile,the methods for reducing lightning loss of automatic weather station are discussed,which can provide references for station operating personnel to troubleshoot and maintain the faults.
作者
徐剑平
臧海光
赵程程
Xu Jianping;Zang Haiguang;Zhao Chengcheng(Weifang Meteorological Bureau,Weifang 261000;Changle Meteorological Bureau,Changle 262400)
出处
《气象水文海洋仪器》
2019年第2期114-116,共3页
Meteorological,Hydrological and Marine Instruments
关键词
新型站
接线图
综合故障
new weather station
wiring diagram
integrated faults