摘要 In this study,batch experiments were conducted to investigate the performance of microscale Fe/Cu bimetallic particles-air-persulfate system(mFe/Cu-air-PS)for p-nitrophenol(PNP)treatment in aqueous solution.First,the optimal operating parameters(i.e.,aeration rate of 1.0 L/min,theoretical Cu mass loading(TMLCu)of 0.110 g Cu/g Fe,mFe/Cu dosage of 15 g/L,PS total dosage of 15 mmol/L,feeding times of PS of 5,initial pH 5.4)were obtained successively by single-factor experiments.Under the optimal conditions,high COD and TOC removal efficiencies(71.0%,65.8%)were obtained after 60 min treatment.Afterword,compared with control experiments(i.e.,mFe/Cu,air,PS,mFe/Cu-air,mFe/Cu–PS,air-PS and mFe-air-PS),mFe/Cu-air-PS system exerted superior performance for pollutants removal due to the synergistic effect between mFe/Cu,air and PS.In addition,the results of control experiments and radical quenching experiments indicate this reinforcement by feeding of PS was greater than by aeration in m Fe/Cu-air-PS system.Furthermore,the degradation intermediates of PNP in mFe/Cu-air-PS process were identified and measured by HPLC.Based on the detected intermediates,the degradation pathways of PNP were proposed comprehensively,which revealed that toxic and refractory PNP in aqueous solution could be decomposed effectively and transformed into lower toxicity intermediates.As a result,m Fe/Cu-air-PS system with the performance of oxidation combined reduction can be also a potential technology for the treatment of toxic and refractory PNP contained wastewater. In this study, batch experiments were conducted to investigate the performance of microscale Fe/Cu bimetallic particles-air-persulfate system(mFe/Cu-air-PS) for p-nitrophenol(PNP) treatment in aqueous solution. First, the optimal operating parameters(i.e., aeration rate of 1.0 L/min, theoretical Cu mass loading(TMLCu) of 0.110 g Cu/g Fe, mFe/Cu dosage of 15 g/L, PS total dosage of 15 mmol/L, feeding times of PS of 5, initial pH 5.4) were obtained successively by single-factor experiments. Under the optimal conditions, high COD and TOC removal efficiencies(71.0%, 65.8%) were obtained after 60 min treatment.Afterword, compared with control experiments(i.e., mFe/Cu, air, PS, mFe/Cu-air, mFe/Cu–PS, air-PS and mFe-air-PS), mFe/Cu-air-PS system exerted superior performance for pollutants removal due to the synergistic effect between mFe/Cu, air and PS. In addition, the results of control experiments and radical quenching experiments indicate this reinforcement by feeding of PS was greater than by aeration in m Fe/Cu-air-PS system. Furthermore, the degradation intermediates of PNP in mFe/Cu-air-PS process were identified and measured by HPLC. Based on the detected intermediates, the degradation pathways of PNP were proposed comprehensively, which revealed that toxic and refractory PNP in aqueous solution could be decomposed effectively and transformed into lower toxicity intermediates. As a result, m Fe/Cu-air-PS system with the performance of oxidation combined reduction can be also a potential technology for the treatment of toxic and refractory PNP contained wastewater.
出处 《Chinese Chemical Letters》 SCIE CAS CSCD 2019年第5期1129-1132,共4页 中国化学快报(英文版)
基金 the financial support from the National Natural Science Foundation of China(No.51878423) China Postdoctoral Science Foundation(No.2018M631077)
关键词 p-Nitrophenol(PNP) Microscale Fe/Cu bimetallic particles(mFe/Cu) Persulfate(PS) AIR aeration mFe/Cu-air-PS system p-Nitrophenol (PNP) Microscale Fe/Cu bimetallic particles (mFe/Cu) Persulfate (PS) Air aeration mFe/Cu-air-PS system
  • 相关文献

同被引文献76

引证文献9

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部