期刊文献+

Hot compression deformation behavior of biomedical Ni-Ti alloy 被引量:5

Hot compression deformation behavior of biomedical Ni-Ti alloy
原文传递
导出
摘要 Biomedical Ti-55.78 (wt%) Ni alloy samples were prepared by vacuum induction melting, and their hot compression deformation behavior was studied in the deformation temperature range of 750-950℃, the strain rate range of 0.001-1.000 s^-1 and the true strain range of 0.1 -0.7. The constitutive equation of the as-cast biomedical Ni-Ti alloy was established based on the Arrhenius constitutive model, and error analysis of the constitutive equation was carried out. The processing zone and unstable thermal deformation zone of the as-cast biomedical Ni-Ti alloy were obtained by establishing hot processing maps based on a dynamic material model. The results showed that deformation temperature and strain rate were the main factors affecting the flow stress. The results of error verification of the constitutive equation show that the predicted flow stress curves agree well with the measured ones. Therefore, the constitutive equation based on Arrhenius can accurately predict the high temperature flow stress of as-cast biomedical Ni-Ti alloy. The optimum parameters for forging process of biomedical Ni-Ti alloy are the strain rate less than 0.003 s^-1 and the hot deformation temperature range of 930-950℃. Biomedical Ti-55.78(wt%)Ni alloy samples were prepared by vacuum induction melting,and their hot compression deformation behavior was studied in the deformation temperature range of 750-950 ℃,the strain rate range of 0.001-1.000 s-1 and the true strain range of 0.1-0.7.The constitutive equation of the as-cast biomedical Ni-Ti alloy was established based on the Arrhenius constitutive model,and error analysis of the constitutive equation was carried out.The processing zone and unstable thermal deformation zone of the as-cast biomedical Ni-Ti alloy were obtained by establishing hot processing maps based on a dynamic material model.The results showed that deformation temperature and strain rate were the main factors affecting the flow stress.The results of error verification of the constitutive equation show that the predicted flow stress curves agree well with the measured ones.Therefore,the constitutive equation based on Arrhenius can accurately predict the high temperature flow stress of as-cast biomedical Ni-Ti alloy.The optimum parameters for forging process of biomedical Ni-Ti alloy are the strain rate less than 0.003 s-1 and the hot deformation temperature range of 930-950 ℃.
出处 《Rare Metals》 SCIE EI CAS CSCD 2019年第7期609-619,共11页 稀有金属(英文版)
基金 financially supported by the National Natural Science Foundation of China (Nos. 51874226 and 21105127) the Fund of the State Key Laboratory of Nickel and Cobalt Resource Integrated Utilization (No. 301170504) Xi’an Science and Technology Planning Project (No. 201805033YD11CG17(8))
关键词 BIOMEDICAL NI-TI ALLOY HOT compression deformation Constitutive equation HOT processing map Biomedical Ni-Ti alloy Hot compression deformation Constitutive equation Hot processing map
  • 相关文献

参考文献8

二级参考文献55

共引文献104

同被引文献13

引证文献5

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部