天津天铁冶金集团有限公司空分厂原氧气透平压缩机的分布式控制系统(DCS)设备老化,已经不能正常工作。介绍了对其进行的改造方案、系统软硬件配置、改造过程中遇到的问题和解决办法。改造后保证了设备的稳定运行。
The equipment of distributed control system(DCS)of the original oxygen turbine compressor in Tianjin Tiantie Metallurgical Group Co.,Ltd.is aging and can no longer work properly.This paper introduces the transformation scheme,the configuration of software and hardware of the system,the problems encountered in the transformation process and the solutions.After the transformation,the stable operation of the equipment is guaranteed.
作者
宋小波
SONG Xiao-bo(Air Separation Branch of Tianjin Tiantie Metallurgical Group Co.,Ltd.,HEBEI 056404)
出处
《天津冶金》
CAS
2019年第3期26-27,30,共3页
Tianjin Metallurgy
关键词
氧气透平压缩机
分布式控制系统
冗余
空分系统
oxygen turbine compressor
distributed control system
redundancy
air separation system