某调距桨装置故障处理

Malfunction Rectification of a Controllable Pitch Device
下载PDF
导出
摘要 针对某型调距桨装置调距故障的现象,从电控系统、液压系统、机械部套展开故障原因分析,并以此为基础开展实际故障排查,通过逐步排查,确定故障原因存在于液控单向阀,更换元件后故障消除,验证了该故障排查方法的正确性。 For the malfunction of a controllable pitch device, the possible causes are analyzed from the aspects of electronic control system, hydraulic system and mechanical parts. The actual fault investigation is carried out based on the analysis. The gradual investigation is carried out and it is determined that the cause of the fault exists in the hydraulic one-way valve. After the valve is replaced, the fault is eliminated, and the correctness of the troubleshooting method is verified.
作者 朱剑 李光 田志文 ZHU Jian;LI Guang;TIAN Zhiwen(Shanghai Marine Equipment Research Institute, Shanghai 200031, China)
出处 《机电设备》 2019年第3期55-57,共3页 Mechanical and Electrical Equipment
关键词 调距桨 故障 电控系统 液压系统 controllable pitch propeller malfunction electronic control system hydraulic system
  • 相关文献

参考文献1

二级参考文献4

  • 1成大先.机械设计手册[M].北京:化学工业出版社,2002..
  • 2Rolls-RoyceAB. K-142 CPP TRAINING MANUAL [ Z ]. 2003.
  • 3SUN HYDRAULICS CORPORATION. Cartridge Valve Technology [ Z ]. 1987.
  • 4REXROTH CORPORATION. Proportional Electrohydraulic Controls[Z]. 1989.