摘要
在考虑变压器油纸绝缘电阻率及相对介电常数受温度影响的基础上,对不同温度下换流变压器主绝缘电场进行了仿真研究,并得到了电场强度变化分布规律。
O n the basis of con sidering the in fluence of temperature on the resistivity and relative permittivity for transformer oil-paper insulation, the main insulation electric fields of converter transformer at different temperature are simulated, and the distribution regu larities of electric field strength are obtained.
作者
王建民
王同同
刘建军
吕殿利
张栋
WANG Jian-min;WANG Tong-tong;LIU Jian-jun;LYU Dian-li;ZHANG Dong(State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, School of Electrical Engineering, Hebei University of Technology, Tianjin 300130, China;Hebei Provincial Key Laboratory of Electromagnetic &Structural Performanee of Power Transmission and Transformation Equipment (Preparation), Baoding Tianwei Baobian Electric Co., Ltd., Baoding 071056, China;Liaoning Railway Vocational and Technical College, Jinzhou 121000, China)
出处
《变压器》
北大核心
2019年第6期54-58,共5页
Transformer
关键词
换流变压器
主绝缘电场
温度影响
Converter transformer
Main insulating electric field
Temperature influence