某30 MW贯流式机组转子中心体裂纹产生原因与处理措施 被引量:2

Causes and Treatment of Rotor Center Part Crack in a 30 MW Bulb Type Tubular Turbine Unit
下载PDF
导出
摘要 某水电厂灯泡贯流式水轮机组转子中心体与励磁引线支撑块焊缝区域反复发现裂纹。转子支臂根部励磁引线支撑块焊缝区域应力集中严重,焊接质量不佳,在交变载荷作用下,裂纹在此区域萌发,扩展到转子中心体。文中介绍了转子中心体裂纹情况,分析了裂纹产生原因,提出了处理措施和对应的焊接工艺。 The cracks were found repeatedly in the weld area between the rotor center part and the magnetic poles wire support block of a bulb type tubular turbine unit.The cracks germinated in the weld area, extended to rotor center part under a action of alternating load, because of existing stress concentration severely in the root of rotor arm and poor welding quality.The paper introduces the crack situation, analyzes the causes and puts forward the treatment measures and the corresponding welding process.
作者 吴正发 袁曙斌 李奇艳 WU Zhengfa;YUAN Shubin;LI Qiyan(Hunan Wuling Power Engineering Co.,Ltd.,Changsha 410004,China)
出处 《湖南电力》 2019年第3期35-38,共4页 Hunan Electric Power
关键词 转子中心体裂纹 灯泡贯流式机组 裂纹处理 焊接工艺 rotor center part crack bulb type tubular turbine unit crack treatment welding process
  • 相关文献

参考文献7

二级参考文献19

  • 1饶德林,陈立功,倪纯珍,朱政强.超声冲击对焊接结构残余应力的影响[J].焊接学报,2005,26(4):48-50. 被引量:62
  • 2张路.WDB620焊接性试验研究[J].宽厚板,2005,11(2):11-15. 被引量:2
  • 3肖可畏,黄伟.WDB620钢焊接性试验及焊接工艺评定[J].水力发电,2005,31(9):48-50. 被引量:10
  • 4哈尔滨大电机研究所.白山电站水轮发电机转子支臂强度计算科学研究报告[R].哈尔滨:哈尔滨大电机研究所,1998..
  • 5自家骢.水轮发电机组检修工艺[M].北京:中国电力工业出版,1982..
  • 6GurneyTR.焊接结构的疲劳[M].周殿群译.北京:机械工业出版社,1988.
  • 7张文钺.焊接冶金学[M].北京:机械工业出版社,1996.26-27.
  • 8GB50205-2001.钢结构工程施工质量验收规范[S].[S].,..
  • 9斯重遥,周振丰,钱百年,等.焊接手册(第2册)[M].北京:机械工业出版社,1992.
  • 10DL5017--1993.压力钢管制造及安装验收规范[S].1993.