摘要 目的评价PICCO监测应用于肺心病合并心力衰竭治疗中的价值。方法选取我院2016年2月—2018年3月收治的肺心病合并心力衰竭患者68例,随机分为常规监测的对照组(34例)与PICCO监测的观察组(34例),观察2组患者肺功能情况、呼吸频率、心率、血气分析。结果与对照组相比,观察组干预后肺功能、呼吸频率、心率、血气分析改善情况更佳,差异具有统计学意义(P<0.05)。结论给予肺心病合并心力衰竭患者PICCO监测,能改善患者临床症状及预后水平,值得借鉴。
作者 弓文董 Gong Wendong
出处 《基层医学论坛》 2019年第22期3137-3138,共2页 The Medical Forum
  • 相关文献

参考文献4

二级参考文献49

  • 1张鸿飞,徐世元.脉搏指示连续心排血量技术在心脏前负荷测量的应用近况[J].国际麻醉学与复苏杂志,2006,27(1):58-60. 被引量:23
  • 2孙辉明,邱海波.血管外肺水监测及其临床应用[J].国际呼吸杂志,2006,26(9):697-700. 被引量:13
  • 3付研,王大为.ESC及美国HFSA急性心力衰竭治疗指南评介[J].中国实用内科杂志,2007,27(12):911-913. 被引量:5
  • 4Lloyd-Jones D,Adams R,Carnethon M, et al. Heart dis- ease and stroke statistics-2009 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee [J]. Circulation,2009,119(3) :e21- el81.
  • 5Phillips CR, Chesnutt MS,Smith SM. Exteavascular lung water in sepsis-asociated acute respiratory diftress syn- drome:indexing with predicted body weight improves cor- relation with severity of illness and survival [J]. Crit Care Med, 2008,36( 1 ) : 69-73.
  • 6Bindels AJ,Van der Hoeven JG,Graafland AD,et al. Re- lationships between volume and pressure measurements and stroke volume in cirtically ill patients [J]. Crit Care, 2000,4(3) : 193-199.
  • 7Ros C, Neil M, David J. Haemodynamic monitoring with pulse-in-duced contour cardiac output (PICCO)in cirti- cal care [J]. Intensive and Critical Care Nursing,2003,8 (12) :301-307.
  • 8Harvey S, Harrison DA,Singer M,et al. Assessment of the clinical effectiveness of pulmonary artery catheters in management of patients in intensive care (PAC-Man):a randomized controlled trial [J]. Lancet,2005,366(9484) : 472-477.
  • 9Ivanov R, Alien J, Calvin JE. The incidence of major mor- bidity in critically ill patients managed with pulmonary artery catheters: a meta analysis[J]. Crit Care Med,2000, 28(3) :615-619.
  • 10Ruperez M,Lopez-Herce J, Garcia C. Comparison be- tween cardiac output measured by the pulmonary arterial thermodilution technique and that measured by the femoral arterial thermodilution technique in a pediatric animal model [J]. Pediatr Cardiol, 2004,25 (1) : 119-123.

共引文献19

同被引文献8

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部