摘要
在模拟焦油吸收装置和中试生物质气化炉系统考察正负压取样方式、粗燃气体积流量、焦油含量、取样时间、粗燃气中水分含量、焦油烘干时间、溶剂蒸发等因素对测定结果的影响。结果表明取样时间及溶剂蒸发是影响焦油测定结果准确性的2个主要因素,最佳的取样分析条件为:负压采样、粗燃气流量不大于2.0 Nm^3/h、焦油吸收时间10~15 min、取样前后量取吸收溶剂体积及60℃条件下焦油烘干6 h。在上述条件下,溶剂吸收-称量法定量焦油的相对误差可小于±5%。
It is important to precisely measure the tar content of syngas in evaluation of biomass gasification technology.Uncertainties of sampling and quantification of tar with solvent absorption and gravimetric measurement(SAGM) is investigated in simulated tar absorption device and syngas from a pilot fixed bed gasifier. The chief factors evolved in such uncertainty analysis include pressure of tar sampling,volumetric flow rate of syngas,mass content of tar in syngas,duration time of tar absorption,and mass content of water in syngas,volume of solvent evaporation during tar absorption process and variations of individual chemicals in tar in drying steps. The results showed that major contributions to the overall uncertainty are related to duration time of tar absorption and solvent evaporation during tar absorption steps. In order to keep the relative error of tar quantification by SAGM within ±5%,the following optimization conditions for tar sampling and measurement are advised,i.e.,tar sampling at negative pressure for 10-15 min,lower the volumetric flow rate of syngas passing the absorption bottles(≤2.0 Nm^3/h),and drying tar samples at 60℃for 6 h.
作者
谢建军
刘华财
李伟振
阴秀丽
吴创之
Xie Jianjun;Liu Huacai;Li Weizhen;Yin Xiuli;Wu Chuangzhi(Key Laboratory of Renewable Energy, Chinese Academy of Sciences, Guangdong Key Laboratory of New and Renewable Energy Research andDevelopment, Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou 510640, China)
出处
《太阳能学报》
EI
CAS
CSCD
北大核心
2019年第6期1701-1708,共8页
Acta Energiae Solaris Sinica
基金
国家自然科学基金(51661145022
51576200)
广东省科技计划(2016A040403097
2014A010106017)
关键词
生物质气化
粗燃气
焦油
测定
相对误差
吸收-分析法
biomass gasification
syngas
tar
quantification
relative error
absorption-analysis