期刊文献+

西门子水冷电机绝缘击穿特性分析及预防

Analysis and Prevention of Siemens Water-Cooled Machine Insulation Breakdown Characteristic
下载PDF
导出
摘要 通过记录西门子1FE1内置水冷电机的接地故障判断过程,对该类型的电机的结构、特点进行了介绍,分析了电机绝缘特性,并利用实际维修经验,例举了引发绝缘击穿的原因,针对性地提出了预防措施和改进思路,为设计人员完善电机性能,提高绝缘强度,提供了现场依据,也为设备维修人员在现场进行类似故障分析提供了思路。 By recording the earth fault judge process of Siemens 1FE1 built-in water-cooled machine,this paper introduced the structure and characteristics of this type of electric machine,analyzed the electric machine insulation characteristic and used the practical service experience to enumerate the causes triggering insulation breakdown.The precautionary measures were pertinently proposed,as well as the improved thoughts,so that the designer has the site gist to improve the motor performance and dielectric strength and the equipment maintenance personnel have the thoughts to carry out the analogous site faults analysis.
作者 刘清 LIU Qing(Chengdu Compressor Branch Office of China Petroleum Group JDEC Power Limited Company, Chengdu 610100, China)
出处 《电工电气》 2019年第7期51-54,共4页 Electrotechnics Electric
关键词 数控龙门镗铣床 水冷电机 变频电机 匝间绝缘 numerical control plano-boring and milling machine water-cooled machine variable frequency motor turn-to-turn insulation
  • 相关文献

参考文献2

二级参考文献24

  • 1J A Oliver and G C Stone. Implications for the application of adjustable speed drive electronics to motor stator winding insulation[J ]. IEEE Electr. Insul. Mag., 1995, (4): 32~ 36.
  • 2A H Bonnett. Analysis of the impact of pulse - width modulated inverter voltage waveforms on A C induction motors[C].IEEE Annual Pulp & Paper Industry Conference Record, 1994, 68~75.
  • 3R Rhudy, E L Owen, D K Sharma. Voltage distribution among the coils and turns of a form wound AC rotating machine exposed to impulse voltage[C].IEEE PES Winter Meeting, 1985, 109~ 114.
  • 4Y Tang. Analysis of steep-fronted voltage distribution and turn insulation failure in inverter-fed form-wound AC motor[C]. IEEE Trans on Industry Applications,1998, (5): 1088~ 1096.
  • 5T Lebey. A theoretical approach of partial discharges under square voltage wave forms[C].Conference Record of the 1998 IEEE International Symposium on Electrical Insulation, Arlington, Virginia, USA, 1998, 257~260.
  • 6W Yin. Failure mechanism of winding insulations in Inverter- fed motors[J]. IEEE Electrical Insulation Magazine,1997, (6): 18~23.
  • 7M Kaufhold, H Auinger, M Berth, et al. Electrial stress and failure mechanism of the winding insulation in PWMInverter-fed low voltage induction motors[J].IEEE Transaction on Industrial Electronics, 2000, (2) :396~402.
  • 8M Kaufhold, G Borner, M Eberhardt, et al. Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controlled inverters[J]. IEEE Electrical Insulation Magazine, 1996, (5): 9~ 16.
  • 9A H Bonnet. Comparison between insulation system available for PWM-inverter-fed motors[J]. IEEE Transaction on Industrial Applications, 1997, (5) :1331~1334.
  • 10D H Hwang, et al. Analysis of insulation characteristics of PWM inverter-fed industrial motors[C]. 2001 IEEE International Symposium on Industrial Electronics(IEEE ISIE - 2001). Pusan, Korea. 2001,477~ 481.

共引文献26