期刊文献+

超声心动图联合CT血管造影成像诊断心脏二尖瓣脱垂的临床价值 被引量:3

Clinical Value of Ultrasonic Cardiogram Combined with CT Angiography in the Diagnosis of Mitral Valve Prolapse
下载PDF
导出
摘要 目的探究超声心动图(UCG)联合CT血管造影(CTA)应用于二尖瓣脱垂(MVP)诊断的临床价值。方法回顾性分析28例MVP患者临床资料,比较UCG、CTA及手术测量病变情况差异,以手术所见为诊断"金标准",分析术前UCG、CTA及二者联合方案的诊断效能差异区别。结果UCG、CTA、手术测量瓣环周长、瓣叶厚度水平及腱索断裂率比较均无统计学意义(P>0.05),而UCG测得瓣环位移水平明显低于手术测量,CTA测得幕状区面积水平明显低于手术测量(P<0.05)。单纯UCG及单纯CTA诊断MVP准确率均明显低于UCG联合CTA方案(P<0.05)。结论UCG与CTA均可获得较为丰富且精确的MVP病变信息,二者联合应用可相互补充以增强诊断效能,临床应用价值较高。 Objective To explore the clinical value of ultrasonic cardiogram (UCG) combined with CT angiography (CTA) in the diagnosis of mitral valve prolapse (MVP). Methods The clinical data of 28 patients with MVP were retrospectively analyzed retrospectively.The differences of lesions condition were compared by UCG,CTA and surgical measurement.The surgical findings were used as the gold standard to analyze the diagnostic efficacy of preoperative UCG,CTA and the combination of the two.Results There were no significant differences in the annulus circumference,valve leaflet thickness and choraetendinae rupture rate by UCG,CTA and surgical measurement (P>0.05),and the annulus displacement level measured by UCG was significantly lower than that by surgical measurement,and the area of tentorial region measured by CTA was significantly lower than that by surgical measurement (P<0.05).The accuracy rate by simple UCG and simple CTA was significantly lower than that by UCG combined with CTA in the diagnosis of MVP (P<0.05).Conclusion Both UCG and CTA can obtain rich and accurate MVP lesion information.The combination of these two methods helps to improve the diagnostic accuracy of the diseaseThe combination of the two can complement each other to enhance the diagnostic efficacy,and it has high clinical application value.
作者 唐浩 黄昊 TANG Hao;HUANG Hao(Department of Ultrasound,Dujiangyan Traditional Chinese Medicine Hospital,Dujiangyan 611830,Sichuan Province,China)
出处 《中国CT和MRI杂志》 2019年第6期73-75,共3页 Chinese Journal of CT and MRI
基金 四川省卫生厅科研项目(130296)
关键词 超声心动图 CT血管造影 二尖瓣脱垂 Ultrasonic Cardiogram CT Angiography Mitral Valve Prolapse
  • 相关文献

参考文献7

二级参考文献43

  • 1钟敏,张淼源,许桃英,刘巾.二尖瓣口平面确定技术在二维超声测量二尖瓣口面积中的临床应用价值[J].中国超声诊断杂志,2005,6(9):661-663. 被引量:7
  • 2丛涛,王珂.经胸二维超声心动图诊断不同部位二尖瓣脱垂的准确性[J].中国循环杂志,2006,21(6):453-456. 被引量:3
  • 3张远慧.二尖瓣脱垂综合征的诊断与治疗[J].新医学,2007,38(7):428-430. 被引量:3
  • 4Alkadhi tt, Wildermuth S, Plass A, et al. Aortic stenosis: comparative evaluation of 16-detector row CT and echocardiography[J]. Radiology, 2006,240(1):47-55.
  • 5LaBounty TM, Sundarain B, Agarwal P, et al. Aortic valve area on 64-MIDCT correlates with transesophageal echocar-diography in aortic stenosis [J]. AJR, 2008,191(12):1652 1658.
  • 6Messika-Zeitoun D, Serfaty JM, Laissy JP, et al. Assessment of the mitral valve area in patients with mitral stenosis by multislice computed tomography[J]. J Am Coll Cardiol, 2006,48(2):411-413.
  • 7Konen E, Goitein O, Feinberg MS, et al. The role of ECG-gated MDCT in the evaluation of aortic and mitral mechanical valves: initial experience[J]. AJR, 2008,191(7):26- 31.
  • 8Willmann JK, Weishaupt D, Lachat M, et al. Electrocardiographically gated multi-detector row CT for assessment of valvular morphology and calcification in aortic stenosis [J]. Radiology, 2002, 225 (1): 120-128.
  • 9Abbara S, Pena AJ, Maurovich-Horvat P, et al. Feasibility and optimization of aortic valve planimetry with MDCT [J]. AJR, 2007,188(2): 356-360.
  • 10Manghat NE, Rachapalli V, Van Lingen R, et al. Imaging the heart valves using ECG-gated 64-detector row cardiac CT[J]. Br J Radio1,2008,81: 275-290.

共引文献22

同被引文献29

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部