介绍了马钢20000m^3/h制氧机膨胀机跳车事故,从电气与控制方面阐述分析了事故原因,通过优化膨胀机控制程序及接线跳车联锁,配置UPS电源及防晃电接触器等措施,解决了膨胀机跳车故障。
The paper introduces a tripping off accident of an expander for MaSteel’s 20000 m^3/h oxygen generator and analyzes the causes of the accident from the aspects of electrics and control system.The tripping problem of the expander was solved by taking measures such as optimization of the control program and wiring a tripping interlock,installing UPS power source and anti-sloshing electric contactor.