摘要 目前人体血糖浓度检测方法往往需要取血测量,不仅费时费力,更加重了糖尿病患者痛苦。为减轻患者痛苦,实现人体血糖浓度快速检测,基于LabVIEW平台设计一种无创血糖浓度检测系统。该系统选用3个固定波长的LED光源生成近红外信号,采用USB-6008数据采集卡进行数据接收与处理,并通过软件设计完成人体血糖浓度检测与显示。实验结果表明,该检测系统可以有效测量、保存人体血糖浓度数据,并实现人体血糖浓度实时监测。 Nowadays,the detection method of human blood glucose concentration often first needs to extract blood for measurement.This method not only takes time and energy,but also increases the pain of diabetic patients.In order to alleviate patients' pain and realize rapid detection of human blood glucose concentration,a non-invasive blood glucose concentration detection system was designed based on LabVIEW platform.The system adopts three fixed wavelength LED light sources to generate near-infrared signals,uses usb-6008 data acquisition card to receive and process data,and completes the detection and display of human blood glucose concentration through software design.After experimental verification,the detection system can effectively measure and preserve the data of human blood glucose concentration and realize real-time monitoring of human blood glucose concentration.
作者 王楚 王亚刚 李文帅 WANG Chu;WANG Ya-gang;LI Wen-shuai(College of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology,Shanghai 200093,China;Hangzhou HuiXin Medical Technology Co.,Ltd.,Hangzhou 310006,China)
出处 《软件导刊》 2019年第7期108-111,共4页 Software Guide
基金 国家自然科学基金项目(61074087)
关键词 人体血糖 近红外 USB-6008 LABVIEW 偏最小二乘法 blood glucose near infrared USB-6008 LabVIEW PLS