期刊文献+

产前三维能量多普勒超声预测前置胎盘患者剖宫产术中出血量 被引量:23

Antenatal 3D power Doppler ultrasound in predicting bleeding volume in patients with placenta previa undergoing cesarean surgery
下载PDF
导出
摘要 目的探讨三维能量多普勒超声(3D-PDU)预测前置胎盘患者剖宫产术中出血量的价值。方法回顾性分析141例前置胎盘患者产前3D-PDU检查结果及其剖宫产术中出血量等资料,其中植入性前置胎盘组66例,非植入性前置胎盘组75例,比较2组间血管指数(VI)、血流指数(FI)和血管血流指数(VFI)和剖宫产术中出血量的差异,分析其相关性,并采用ROC曲线评价各参数预测术中出血量的效能。结果植入性前置胎盘组产前VI、FI、VFI和术中出血量均大于非植入性前置胎盘组(P均<0.05)。141例前置胎盘患者中,产前VI和VFI与剖宫产术中出血量均成正相关(r=0.702、0.737,P均<0.001)。植入性前置胎盘组中,VI、FI及VFI均与剖宫产术中出血量呈正相关(r=0.680、0.492、0.722,P均<0.001);非植入性前置胎盘组中,VI、VFI与剖宫产术中出血量呈正相关(r=0.861、0.832,P均<0.001)。141例前置胎盘患者VI、FI和VFI的ROC曲线AUC分别为0.911、0.798、0.937(P均<0.001);植入性前置胎盘组为0.966、0.722、0.938(P均<0.05);非植入性前置胎盘组为0.885、0.856、0.966(P均<0.001)。结论产前3D-PDU可用于预测前置胎盘患者剖宫产术中出血量。 Objective To explore the value of three-dimensional power Doppler ultrasound (3D-PDU) in predicting bleeding volume during cesarean surgery in patients with placenta previa.Methods Clinical data of 141 patients with placenta previa who underwent 3D-PDU examinations before cesarean surgery and the bleeding volume during cesarean surgery were retrospectively reviewed.The patients were classified into implanted placenta previa group (n=66) and non-implanted placenta previa group (n=75).The differences of vascularization index (VI),flow index (FI),vascularization flow index (VFI) and bleeding volume were compared between the 2 groups,and the correlation was analyzed.ROC curve was used to evaluate the efficacy of each index in predicting bleeding volume during cesarean surgery.Results Antenatal VI,FI,VFI and bleeding volume of the implanted placenta previa group were higher than those of non-implanted placenta previa group (all P<0.05).In all 141 patients,VI and VFI were positively correlated with the bleeding volume during cesarean surgery (r=0.702,0.737,both P<0.001).In implanted placenta previa group,VI,FI and VFI were positively correlated with the bleeding volume in cesarean section (r=0.680,0.492,0.722,all P<0.001).In non-implanted placenta previa group,VI and VFI were positively correlated with the bleeding volume during cesarean surgery (r=0.861,0.832,both P<0.001).The area under ROC curve of VI,FI and VFI in all 141 patients were 0.911,0.798 and 0.937 (all P<0.001),in implanted placenta previa group were 0.966,0.722 and 0.938 (all P<0.05),while in non-implanted placenta previa group were 0.885,0.856 and 0.966,respectively (all P<0.001).Conclusion Antenatal 3D-PDU can be applied in predicting bleeding volume in patients with placenta previa during cesarean surgery.
作者 解艳华 张庆桥 朱秀娟 徐平平 王睿婕 左云鹏 张丽 XIE Yanhua;ZHANG Qingqiao;ZHU Xiujuan;XU Pingping;WANG Ruijie;ZUO Yunpeng;ZHANG Li(Department of Ultrasound,the Affiliated Xuzhou Maternity and Child Health Care Hospital of Xuzhou Medical University,Xuzhou 221009,China;Department of Interventional Radiology,the Affiliated Hospital of Xuzhou Medical University,Xuzhou 221006,China)
出处 《中国医学影像技术》 CSCD 北大核心 2019年第7期1076-1080,共5页 Chinese Journal of Medical Imaging Technology
关键词 前置胎盘 剖宫产术 出血量 超声检查 多普勒 placenta previa cesarean section bleeding volume ultrasonography,Doppler
  • 相关文献

参考文献11

二级参考文献86

  • 1张超学,张新书,王玲,孔晓春,王惠民,朱建元,陈庆,张萌.乳腺肿瘤三维超声血管容积指数及二维超声彩色像素密度与病理微血管密度相关性的对比研究[J].中华超声影像学杂志,2006,15(2):157-158. 被引量:9
  • 2Raine-Fenning NJ, Nordin NM, Ramnarine KV, et al .Determin- ing the relationship between three-dimensional power Doppler data and true blood flow characteristics : an in-vitro flow phantom experiment [ J ]. Ultrasound Obstet Gynecol , 2008,32 (4) : 540-550.
  • 3Raine-Fenning NJ, Nordin NM, Ramnarine KV, et al. Evaluation of the effect of machine settings on quantitative three-dimensional power Doppler angiography: an in-vitro flow phantom experiment [J ]. Ultrasound Obstet Gyneeol , 2008,32 (4) : 551-559.
  • 4Raine-Fenning NJ, Ramnarine KV, Nordin NM ,et al. Quantifica- tion of blood perfusion using 3D power Doppler: an in-vitro flow phantom study[J]. JPCS, 2004, 1 : 181-186.
  • 5Dubiel M, Hammid A, Breborowicz A ,et al. Flow index evaluation of 3-D volume flow images: An in vivo and in vitro study [J]. Ultrasound Med Biol,2006,32 (5) : 665-671.
  • 6Rovas L, Sladkevicius P, Strobel E ,et al. Intraobserver and interobserver reproducibility of three-dimensional gray-scale and power Doppler ultrasound examinations of the cervix in pregnant women. [J ]. Ultrasound Obstet Gynecol, 2005,26 (2) : 132-137.
  • 7Raine-Ferming NJ, Campbell BK, Clewes JS, et al. The reliability of virtual organ computer-aided analysis (VOCAL) for the semiquantification of ovarian, endometrial and subendometrial perfusion [ J ]. Ultrasound Obstet Gynecol, 2003,22 (6) : 633-639.
  • 8Merce LT, Barco MJ, Bau S. Reproducibility of the study of placental vascularization by three-dimensional power Doppler [J].J Perinat Med , 2004,32 (3) : 228-233.
  • 9Merce LT, Barco M J, Bau S, et al. Assessment of placental vascularization by three-dimensional power Doppler "vascular biopsy" in normal pregnancies [ J ]. Croat Med J, 2005,46 (5) : 765-771.
  • 10Zalud I, Shaha S. Evaluation of the utero-placental circulation by three-dimensional Doppler ultrasound in the second trimester of normal pregnancy [J]. J Matem Fetal Neonatal Med, 2007,20 (4) : 299-305.

共引文献312

同被引文献228

引证文献23

二级引证文献88

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部