期刊文献+

全模型迭代重建算法在CT血管成像中的应用进展 被引量:3

Research progress of iterative model reconstruction in CT angiography
下载PDF
导出
摘要 全模型迭代重建(IMR)技术作为一种新型的迭代重建算法,与传统滤波反投影法及混合迭代算法比较,在降低噪声、提高图像质量效果方面表现更为出色。IMR技术的使用可以在降低辐射剂量的同时,又能确保图像的质量并能够良好的完成诊断。本文就IMR技术在各部位CT血管成像中的临床应用进展进行综述,并对做出简单预估,为相关研究提供参考。 Iterative model reconstruction(IMR) technology is a new type of iterative reconstruction algorithm. Compared with the traditional filtered back projection and hybrid iterative algorithm, it performs better in reducing noise and improving image quality. Application of IMR reconstruction can reduce the radiation dose and ensure the image quality.In this paper, the clinical application progress of IMR technology in CT angiography of various parts is reviewed, and a simple estimation is made to provide reference for related research.
作者 安子晨 肖喜刚 张金玲 吕亚会 李茂桐 AN Zichen;XIAO Xigang;ZHANG Jinling;LYU Yahui;LI Maotong(Department of Radiology, the First Affiliated Hospital of Harbin Medical University, Heilongjiang Province, Harbin 150001, China;Department of Radiology, Harbin Second People′s Hospital, Heilongjiang Province, Harbin 150056, China)
出处 《中国医药导报》 CAS 2019年第19期58-61,共4页 China Medical Herald
基金 黑龙江省卫生计生委科研题目(2014-268)
关键词 全模型迭代重建 滤波反投影 体层摄影术 X线计算机 CT血管成像 Iterative model reconstruction Filtered back projection Tomography X-ray computed CT angiography
  • 相关文献

参考文献8

二级参考文献59

  • 1黄飚,梁长虹,张云亭,周东,林华欢,茹光腾,刘红军,刘其顺.星形细胞肿瘤CT灌注成像与肿瘤微血管相关性的研究[J].实用放射学杂志,2005,21(5):463-467. 被引量:17
  • 2张永海,白俊虎,张明,杨国才,唐桂波,方军,史伟,李兴华,刘素萍,卢青,唐军.超急性期及急性期脑梗死全脑CT灌注和CT血管造影研究[J].中华放射学杂志,2005,39(7):681-686. 被引量:27
  • 3Wintermark M, Lev MH. FDA investigates the safety of brain perfusion CT. Am J Neuroradiol, 2010, 31(1): 2-3.
  • 4Wintermark M, Flanders AE, Velthuis B, et al. Perfusion-CT assessment of infarct core and penumbra: receiver operating characteristic curve analysis in 130 patients suspected of acute hemispheric stroke. Stroke, 2006, 37(4): 979-985.
  • 5Wintermark M. Brain perfusion-CT in acute stroke patients. Eur Radiol, 2005, 15(Suppl 4): D28-31.
  • 6Smith WS, Lev MH, English JD, et al. Significance of large vessel intracranial occlusion causing acute ischemic stroke and TIA. Stroke, 2009, 40( 12): 3834-3840.
  • 7Hunter G J, Hamberg LM, Ponzo JA, et al. Assessment of cerebral perfusion and arterial anatomy in hyperacute stroke with three-dimensional functional CT: early clinical results. Am J Neuroradiol, 1998, 19(1): 29-37.
  • 8Brenner D J, Hall EJ. Computed tomography--an increasing source of radiation exposure. N Engl J Med, 2007, 357(22): 2277-2284.
  • 9Korn A, Fenchel M, Bender B, et al. Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection. Am J Neuroradiol, 2012, 33(2): 218-224.
  • 10Wintermark M, Maeder P, Verdun FR, et al. Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow. Am J Neuroradiol, 2000, 21(10): 1881- 1884.

共引文献112

同被引文献24

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;