摘要
In consideration of geometric parameters, several researches have already optimized the thermal efficiency of the cylindrical cavity receiver. However, most of the optimal results have been achieved at a fixed solar radiation. At different direct normal irradiance (DNI), any single optimal result may not be suitable enough for different regions over the world. This study constructed a 3-D numerical model of cylindrical cavity receiver with DNI variation. In the model of a cylindrical cavity receiver containing a helical pipe, the heat losses of the cavity and heat transfer of working medium were also taken into account. The simulation results show that for a particular DNI in the range of 400 W/m2 to 800 W/m2, there exists a best design for achieving a highest thermal efficiency of the cavity receiver. Besides, for a receiver in constant geometric parameters, the total heat losses increases dramatically with the DNI increasing in that range, as well as the temperature of the working medium. The thermal efficiency presented a different variation tendency with the heat losses, which is 2.45% as a minimum decline. In summary, this paper proposed an optimization method in the form of a bunch of fitting curves which could be applied to receiver design in different DNI regions, with comparatively appropriate thermal performances.