摘要 2017年,最新的国家标准《测量不确定度评定和表示》(GB/T 27418—2017)发布。目前,测量不确定度的方法中,GUM法中一系列Bottom-Up方法的使用较为普遍。《基于质控数据环境检测测量不确定度评定指南》(CNAS-GL34)提出使用Top-Down方法进行不确定度的评定。以纳氏比色法测定水中氨氮的检测数据为基础,考察GUM法中最小线性二乘法和Top-Down法中质控图法两种方法评定检测数据的不确定度,比较分析了两种方法的优劣,初步探讨了Top-Down方法的应用前景。 In 2017,the latest national standard Measurement Uncertainty Evaluation and Representation(GB/T 27418—2017)was released.In the current method of measuring uncertainty,a series of Bottom-Up methods in GUM are more common.However,CNAS-GL34 based on the Quality Control Data Environment Measurement and Measurement Uncertainty Evaluation Guide proposes the use of Top-Down method for the evaluation of uncertainty.Based on Nash colorimetric method for the determination of ammonia nitrogen in water,the uncertainty of the test data is evaluated by the minimum linear multiplication method in GUM and the quality control chart method in Top-Down.The pros and cons of the method,and the application prospects of Top-Down method are discussed.
作者 徐呈豪 XU Chenghao(Shanghai Municipal Water Supply Dispatching and Monitoring Center,Shanghai 200002,China)
出处 《净水技术》 CAS 2019年第A01期25-28,共4页 Water Purification Technology
基金 金泽水库水质调控与稳定关键技术研究与应用(2017ZX07207003)
关键词 最小线性二乘法 Top-Down法 纳氏比色法 水中氨氮 least linear multiplication Top-Down method Nessler colorimetry ammonia nitrogen in water