期刊文献+

空调室外机管路系统的减振分析 被引量:1

The Air Conditioner Outdoor Unit Vibration Analysis of Piping System
下载PDF
导出
摘要 空调压缩机工作时会间歇性的吸气和排气,这将会导致压缩机产生相应的振动,而振动将会传递到与之相连的管路上,管路在长期振动下容易断裂导致冷媒的泄漏。通过有限元仿真软件对管路系统进行了模态分析和谐响应分析,并通过增加消声器和增加管路壁厚的方法对管路进行减振分析,通过优化管路系统降低管路振幅,提高管路使用寿命。 The air conditioner outdoor unit of piping system will produce corresponding vibration.The pipeline is easy to break under the long-term vibration,which leads to the leakage of refrigerant.In this paper,the modal analysis and harmonic response analysis of pipeline system are carried out by finite element simulation software.The vibration reduction of pipelines is analyzed by adding mufflers and increasing the thickness of pipelines.By optimizing pipeline system,reducing pipeline amplitude and improving pipeline service life.
作者 张宁波 ZHANG Ning-bo(Guangzhou Huali Science and Technology Vocational College,Guangzhou 511325,China)
出处 《机电工程技术》 2019年第6期56-57,116,共3页 Mechanical & Electrical Engineering Technology
基金 国家自然科学基金资助项目(编号:51405083)
关键词 管路振动 有限元 模态分析 谐响应分析 pipeline vibration ANSYS modal analysis harmonic response analysis
  • 相关文献

参考文献8

二级参考文献16

共引文献56

同被引文献2

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部