期刊文献+

基于ZEMAX的二氧化硫分析仪光学设计 被引量:1

Optical Design of Sulfur Dioxide Analyzer Based on ZEMAX
下载PDF
导出
摘要 鉴于二氧化硫分析仪中国标推荐的分析方法为紫外荧光法,根据此原理对两种光路进行了光学设计,并在ZEMAX中进行仿真和优化,结果显示:光路1的最终能量百分比为49%,光路2为9%;光路1的PMT位置光束半径为2.738mm,光路2为1.291mm。 The analytical method recommended by the Chinese standard for sulfur dioxide analyzer is ultraviolet fluorescence method.According to this principle,the optical design of two optical paths is carried out,and the simulation and optimization are carried out in ZEMAX.The results show that the final energy percentage of optical path one is 49%,and that of optical path two is 9%.The beam radius at the PMT position of optical path one is 2.738 mm,while that of optical path two is 1.291 mm.
作者 李洪刚 吴岩磊 LI Honggang;WU Yanlei(Tianjin Shareshine Technology Development Co.Ltd.,Tianjin 300384,China;Tianjin Environmental Monitoring Technology Enterprise Key Laboratory,Tianjin 300384,China)
出处 《天津科技》 2019年第7期54-56,共3页 Tianjin Science & Technology
基金 天津市科技计划项目“基于‘先进云’工业园区环境监控预警和风险应急管理系统”(16YFXTSF00370)
关键词 二氧化硫分析仪 ZEMAX 光学设计 紫外荧光法 sulfur dioxide analyzer ZEMAX optical design ultraviolet fluorescence method
  • 相关文献

参考文献2

二级参考文献8

共引文献39

同被引文献13

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部