摘要 基于北京地区2014年1月1日至2016年12月31日室外PM2.5小时平均值和日平均值质量浓度数据,采用日平均质量浓度统计法与小时平均质量浓度统计法,比较分析了3种常用统计计算方法(历年不保证天数法、累年不保证天数法、历年不保证小时数法)的统计计算结果对新风过滤装置设计选型的影响。研究结果表明:关于室外PM2.5计算质量浓度值,对于新风过滤系统,建议按历年不保证小时数法确定;对于以白天工作为主的场所(如学校、办公建筑等),建议按照历年不保证小时数法的白天时段(07:00至次日19:00)的统计计算结果取值;对于室内环境质量要求较高或全天候或夜间工作为主的场所,建议按照历年不保证小时数法的夜间时段(20:00至次日06:00)的统计计算结果取值。 Based on the outdoor hourly mean mass concentration and daily mean mass concentration data in Beijing from January 1, 2014 to December 31, 2016, compares and analyses the impacts of the statistical calculation results using three common statistical calculation methods (annual non-guaranteed number of days, normal non-guaranteed number of days and annual non-guaranteed number of hours) on the design and selection calculation of the outdoor air filter. The results show that the annual non-guaranteed number of hours is suggested to determinate outdoor PM2.5 calculation mass concentration for the outdoor air filtration system, the annual non-guaranteed number of hours (during the day time 07:00-19:00) is suggested for the place where working mostly during the day, and the annual non-guaranteed number of hours (during the night time 20:00-06:00) is suggested for the place where high environment required and working all the day and night or during the night.
作者 吴玉琴 陈超 陈紫光 郝梓仰 蔺洁 Wu Yuqin;Chen Chao;Chen Ziguong;Hao Ziyong;Lin Jie(Beijing University of Technology,Beijing,China)
机构地区 北京工业大学
出处 《暖通空调》 2019年第7期83-87,55,共6页 Heating Ventilating & Air Conditioning
基金 “十三五”国家重点研发计划项目(编号:2017YFC0702800,2016YFC0700206)
关键词 室外细颗粒物污染 空气过滤系统 计算质量浓度 计算方法 比较 outdoor fine particulate matter pollution air filtration system calculation mass concentration calculation method comparison
  • 相关文献

参考文献8

二级参考文献91

共引文献116

同被引文献28

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部