介绍了变风量空调系统常用的新风控制策略,分析了基于CO2浓度模型的新风量计算方法。通过对比试验研究了定新风比与变新风比控制策略在系统新风量及各区域新风量分配方面的控制效果,结果表明,2种控制策略均存在新风分配不均的问题。在此基础上,试验研究了变新风比控制策略对室内空气品质的控制效果及节能性。结果表明,在实现相同室内空气品质控制效果的前提下,与基于maxY方程的变新风比策略(maxY-V)相比,基于MSE方程的变新风比策略(MSE-V)能够更大程度地降低能耗,相同工况下,MSE-V策略的空调系统能耗较maxY-V策略低6.76%。
Presents the common outdoor air control strategies used in VAV air conditioning system, analyses the calculation method of outdoor air rate based on CO2concentration model.Studies the control effect of constant outdoor air ratio and variable outdoor air ratio control strategies on outdoor air distribution in a whole system and different parts through comparative experiments.The results show that the uneven distribution of outdoor air exists in both control strategies.On this basis,experimentally studies the control effect and energy saving of variable outdoor air ratio control strategy on indoor air quality.The results show that,compared with maxY-V,MSE-V can reduce energy consumption to a greater extent under the same indoor air quality control effect,and under the same conditions,the energy consumption of air conditioning system with MSE-V strategy is 6.76%lower than that with maxY-V strategy.
作者
赵天怡
范朋丹
刘超
王秀波
Zhao Tianyi;Fan Pengdan;Liu Chao;Wang Xiubo(Dalian University of Technology,Dalian,Liaoning Province,China)
出处
《暖通空调》
2019年第7期99-105,共7页
Heating Ventilating & Air Conditioning
基金
国家重点研发计划项目(编号:2017YFC0704100)
辽宁省自然科学基金指导计划项目(编号:20180551057)
大连市高层次人才创新支持计划项目(青年科技之星)(编号:2017RQ099)
国家自然科学基金项目(编号:51578102)
关键词
变风量空调系统
新风控制策略
新风量分配
室内空气品质
节能
variable air volume(VAV)air conditioning system
outdoor air control strategy
outdoor air distribution
indoor air quality
energy saving