摘要 河源市某企业由于在锅炉停用期间的维护不到位,导致钠离子交换器的树脂发生"中毒"现象。本文采用宏观判断及分析的方法,找出了001×7钠离子交换树脂"中毒"的原因是微生物污染。针对被污染的树脂,采用1.5%的甲醛溶液浸泡清洗的方法进行"复苏"。实施后效果显著,出水达到TSGG5002《锅炉水(介)质处理检验规则》的要求。 The resin of the sodium ion exchanger was "poisoned" due to the lack of maintenance during the suspension of the boiler in a company of Heyuan City. This paper found out that the "poisoning" reason of 001×7 sodium ion exchange resin is caused by microbial pollution by using macroscopical judgment and analysis. For the contaminated resin, the method of 1.5 % formaldehyde solution immersion cleaning was used for "recovery". After the implementation, the effect is remarkable, and the outflow water meets the requirements of TSG G5002 "Boiler Water(Medium) Treatment Inspection Regulation.
作者 程明 Cheng Ming(Heyuan Testing Institute of Guangdong Province Special Equipment Inspection Institute Heyuan 517000)
出处 《中国特种设备安全》 2019年第6期69-72,共4页 China Special Equipment Safety
关键词 钠离子交换器 树脂 微生物 污染 Sodium ion exchanger Resin Microorganism Pollution