目的探讨冠状动脉CT血管成像(CCTA)iDose4迭代重建技术在冠状动脉心肌桥检测中的应用价值。方法选择2015-2018年在上海市徐汇区中心医院至少进行过一次滤波反投影(FBP)重建和iDose4迭代重建的41例CCTA检查的患者。患者均采用64层螺旋CT机进行冠状动脉CT血管成像,并进行FBP重建和iDose4迭代重建,对比2种重建方式对冠状动脉心肌桥检出情况,同时计算两者图像信噪比(SNR)和对比噪声比(CNR)。结果iDose4显示冠状动脉心肌桥检出率(58%,24/41)略高于FBP(51%,21/41),但差异无统计学意义(P>0.05);iDose4组心肌桥检出数量(32处)高于对FBP(26处);Dose4图像质量评分(2.8±0.8)分与FBP(12±4)分比较,差异无统计学意义(P>0.05);iDose4图像SNR(12±4)分和CNR(18±6)分与FBP图像(2.8±0.7)分、(13±4)分比较,差异无统计学意义(P>0.05)。结论冠状动脉CT血管成像iDose4迭代重建技术对冠状动脉心肌桥检测准确性较高,且辐射量较低,可为该病临床诊断提供可靠依据。
Objective To evaluate the value of i Dose 4 iteration reconstruction technique in coronary CT angiography(CCTA) in detecting coronary myocardial bridge. Methods Forty-one CCTA patients who underwent FBP reconstruction and iDose 4 iteration reconstruction at least once in Shanghai Xuhui District Central Hospital from2015 to 2018 were selected. All patients underwent 64-slice spiral CT angiography of coronary artery, FBP reconstruction and iDose 4 iteration reconstruction. The detection of coronary myocardial bridge was compared between the two reconstruction methods, and the signal-to-noise ratio(SNR) and contrast-to-noise ratio(CNR) were calculated.Results iDose 4 showed that the detection rate of coronary myocardial bridges(58%,24/41) was slightly higher than that of FBP(51%,21/41), but there was no significant difference(P>0.05);the number of myocardial bridges detected in iDose 4 group(32 sites) was higher than that of FBP(26 sites);there was no significant difference in Dose4 image quality score(2.8±0.8 points) compared with FBP(12.4±4.2 points)(P>0.05);and the SNR of iDose 4 image(12±4 points) had no significant difference. There was no significant difference between CNR(18.0±6.2) and FBP(2.8±0.7) and(13±4)(P>0.05). Conclusion IDose 4 iteration reconstruction technique of coronary CT angiography has high accuracy in detecting coronary myocardial bridge and low radiation dose, which can provide reliable basis for clinical diagnosis of this disease.
作者
明康
杨利霞
符忠祥
朱勇
刘春
周德
许永华
Ming kang;Yang Lixia;Fu Zhongxiang;Zhu Yong;Liu Chun;Zhou De;Xu Yonghua(Department of Radiology,Xuhui District Central Hospital,Shanghai 200031,China)
出处
《实用医学影像杂志》
2019年第3期271-273,共3页
Journal of Practical Medical Imaging
关键词
心脏影像技术
冠状动脉疾病
心肌桥
Cardiac imaging techniques
Coronary disease
Myocardial bridging