针对燃煤锅炉排烟温度高的问题,设计出分段式烟气冷却器方案,并以某电厂630 MW机组增加烟气冷却器改造为例,采用了低温段烟气冷却器控制排烟温度、高温段烟气冷却器控制电除尘器入口烟温的控制策略。结果表明:改造后能有效控制排烟温度、提高锅炉热效率,对同类型机组的改造具有借鉴意义。
To solve the problem of high exhaust gas temperature of a coal-fired boiler,a new scheme of sectional type flue gas cooler was designed.Taking the retrofit on a 630 MW power unit by adding flue gas cooler as an example,where the exhaust gas temperature was controlled by the section of low-temperature flue gas cooler,and the inlet temperature of electrostatic precipitator was controlled by the section of high-temperature flue gas cooler.Results show that after retrofit,the exhaust gas temperature could be controlled effectively,while the boiler efficiency be improved,which therefore may serve as a reference for retrofit of similar power units.
作者
郭伯春
赖海兵
肖胜
Guo Bochun;Lai Haibing;Xiao Sheng(Sichuan Guang’an Power Generation Co.,Ltd.,Guang’an 638000,Sichuan Province,China;China Aviation Industry Nanchong Renewable Energy Co.,Ltd.,Nanchong 637000,SichuanProvince,China;Xi’an Thermal Power Research Institute Co.,Ltd.,Xi’an 710032,China)
出处
《发电设备》
2019年第4期268-272,共5页
Power Equipment
关键词
分段式烟气冷却器
排烟温度
凝结水
控制策略
sectional flue gas cooler
exhaust gas temperature
condensate
control strategy