选取某超高层写字楼,在各楼层疏散宽度满足按照百人宽度指标要求前提下,采用Pathfinder进行数值模拟分析,通过改变疏散楼梯数量和单部楼梯疏散宽度等参数,研究不同疏散场景下的人员整体疏散时间、疏散至避难层的时间以及不同区域(高区、中区和低区)疏散完毕的时间,分析疏散楼梯数量和单部楼梯疏散宽度对人员疏散时间的影响。引入单部疏散楼梯效率指数,结合单部疏散楼梯净宽度等因素对疏散总时间的影响,得出较优设计方案,为类似建筑疏散设计提供参考。
Taking a super high-rise office building as example, under the condition of evacuation width of each floor meets the requirement of 100-person width index, Pathfinder was used for the simulation. By changing the number of evacuation staircases and the evacuation width of single staircase,etc., the overall evacuation time, the time from evacuation to shelter level and the time of completion of evacuation in different areas(high,middle and low areas) were studied in different evacuation scenarios. The influence of the number of evacuation stairs and the evacuation width of a single staircase on evacuation time was analyzed. Introducing the efficiency index of single evacuation stair, combining with the influence of the net width of a single evacuation staircase on the total evacuation time, the better design scheme was obtained to provide reference for evacuation design of similar buildings.
作者
谢天光
路世昌
黄鑫
XIE Tian-guang;LU Shi-chang;HUANG Xin(Tianjin Fire Research Institute of MEM, Tianjin 300381, China)
出处
《消防科学与技术》
CAS
北大核心
2019年第6期786-788,共3页
Fire Science and Technology
基金
国家重点研发计划项目“人员安全疏散智能诱导技术与系统”(2016YFC0800602)
公安部消防局应用创新项目“大型商业综合体消防安全管理研究”(2017XFCX15)
关键词
超高层建筑
安全疏散
数值模拟
疏散效率
super high-rise building
safety evacuation
numerical simulation
evacuation efficiency