摘要 简单介绍某压水堆核电机组汽轮机调节保护系统硬件结构、网络构架,详细介绍该机组在冲转过挂闸后升速到100r/min时,汽轮机发生意外跳机的事件原因。通过对跳机过程、跳闸逻辑、VICKERS卡和汽机调节系统组态的分析,找出汽轮机跳机的真正原因,并提出切实可行的办法,解决了首次冲转跳机问题,并为后续汽轮机冲转提供宝贵的经验。 The hardware and network of one PWR steam turbine's protection and control system are introduced,and the steam turbine trip event cause is introduced in detail during speeding up to 100 RPM.The real reason of the steam turbine trip is found out by analysising the trip process,trip logic design,VICKERS card configuration and turbine control system configuration.After that,a feasible solution is proaided which is checked by the later non-nuclear rushing,and the conclusion also provides valuable experience for subsequent turbine rushing test.
作者 李本荣 杨晓东 马宁 LI Benrong;YANG Xiaodong;MA Ning(Fusing nuclear power Co.Ltd the third,maintenance department Fuqing Fujian Province)
出处 《自动化与仪器仪表》 2019年第7期197-199,共3页 Automation & Instrumentation
关键词 汽轮机 跳机 VICKERS 汽机控制组态 steam turbine turbine trip VICKERS turbine control configuration