期刊文献+

烧烤制品菌落总数检验中不确定度的评定 被引量:2

Uncertainty Evaluation of Aerobic Plate Count in Grilled Meat
下载PDF
导出
摘要 目的建立适用于烧烤制品中菌落总数检测结果的不确定度评定方法。方法依据JJF1059.1-2012《测量不确定度评定与表示》和GB 4789.2-2016《食品安全国家标准食品微生物学检验菌落总数测定》,以及相关统计学方法对样品不确定度进行评定。结果通过统计学分析得出,合并样本标准差为0.0346,取置信水平P=95%,其扩展不确定度为0.0546。结论用此类方法评定多个同类样本的不确定度比较方便,所得结果可随时加入到其余样本中。 Objective To establish a method of uncertainty evaluation for the detection of aerobic plate count in grilled meet.Methods Based on JJF1059.1-2012 Evaluation and Expression of Uncertainty in Measurement,GB4789.2-2016 Microbiological Examination of Food Hygiene-Detection of Aerobic Bacterial Count,and related statistical methods to evaluate uncertainty of the samples.Results According to the methods used,the pooled standard deviation was 0.0346 and the expanded uncertainty was 0.0546(P=95%).Conclusion This method is convenient for uncertainty evaluation of aerobic plate count of multiple similar samples,the result could be calculated again when other samples were added.
作者 张云龙 黄启红 熊娟 黄璇莹 伍玲燕 陈敏儿 Zhang Yunlong;Huang Qihong;Xiong Juan;Huang Xuanying;Wu Lingyan;Chen Miner(Guangdong Provincial Key Laboratory of Emergency Test for Dangerous Chemicals,China National Analytical Center,Guangzhou 510070,China)
出处 《山东化工》 CAS 2019年第14期117-119,共3页 Shandong Chemical Industry
关键词 烧烤制品 菌落总数 不确定度 grilled meat aerobic plate count uncertainty