期刊文献+

全装配下沉式楼板锚栓式连接面内抗剪性能研究 被引量:2

RESEARCH ON THE IN-PLANE SHEAR BEHAVIOR OF ANCHOR BOLTED CONNECTION IN TOTAL-PREFABRICATED SINKING RC FLOOR
原文传递
导出
摘要 全装配下沉式楼板是一种新型干式楼盖体系,其楼板与钢梁之间、楼板与楼板之间分别以锚栓连接。以应用于楼板与楼板间的锚栓式连接为研究对象,以锚栓式连接的锚栓直径、强度、间距和边距,连接钢板厚度和锚固长度,板缝宽度,连接凹槽深度,以及连接钢板与混凝土间的摩擦系数为参数,通过对其进行平面内剪切荷载作用下的数值模拟分析,研究连接细部构造对其面内抗剪强度和刚度的影响。分析结果表明:连接钢板锚固长度不宜小于12倍的钢板厚,连接凹槽深度宜取板厚的50%,锚栓间距宜取3倍的锚栓直径,锚栓边距宜取2~3倍的锚栓直径,板缝宽度不宜超过20mm。 The total-prefabricated sinking reinforced concrete (RC) floor is a new floor system. The connection between slab and steel beam,slab and slab are connected by the anchor bolted connection. The anchor bolted connection applied between slab and slab was taken as the study subject. Considering the parameters,such as the diameter and strength of anchor bolt,the spacing and edge distance of anchor bolt,the thickness and anchorage length of steel plate,the width of slab joint,the depth of connection groove,the friction coefficient between steel plate and concrete,the effects of detailed formations on the in-plane strength and stiffness of bolted connection were studied through numerical simulation analysis of it under in-plane shear force. The analysis results showed that the anchorage length of steel plate should not be less than 12 times of steel plate thickness,the depth of connection groove should be half of slab thickness,the spacing of anchor bolt should be 3 times of the diameter of bolt,the edge distance of anchor bolt should be 2~ 3 times of the diameter of bolt,the width of slab joint should not exceed 20 mm.
作者 李建峰 南晓东 郁有升 LI Jianfeng;NAN Xiaodong;YU Yousheng(Qingdao Tengyuan Design Institute Co.,Ltd.,Qingdao 266100,China;School of Civil Engineering,Qingdao University of Technology,Qingdao 266033,China)
出处 《工业建筑》 CSCD 北大核心 2019年第6期176-182,198,共8页 Industrial Construction
基金 山东省自然科学基金(ZR2017MEE068)
关键词 细部构造 全装配下沉式楼板 锚栓式连接 抗剪性能 detailed formation total-prefabricated sinking RC floor anchor bolted connection shear behavior
  • 相关文献

参考文献7

二级参考文献62

  • 1于安麟,永毓栋,郭在田.钢柱脚在不同弯剪比时的抗剪性能研究[J].工业建筑,1994,24(1):23-27. 被引量:13
  • 2薛立红,蔡绍怀.钢管混凝土柱组合界面的粘结强度(上)[J].建筑科学,1996,12(3):22-28. 被引量:77
  • 3侯雪岩 骆万康.装配式钢筋混凝土楼盖在水平荷载往复作用下的变形性能.重庆建筑工程学院学报,1985,(2):36-51.
  • 4Yee A A. Social and Environmental Benefits of Precast Concrete Technology [J]. PCI Journal, 2001,46(3) : 14 -19.
  • 5Yee A A. Structural and Economic Benefits of Precast! Prestressed Concrete Construction [ J]. PCI Journal, 2001, 46 (3) : 34 -42.
  • 6PCI Industry Handbook Committee. PCI Design Handbook: Precast and Prestressed Concrete [ S ]. 6thed. Chicago: PCI, 2004.
  • 7Cao L, Naito C. Design of Precast Diaphragm Chord Connections for In-Plane Tension Demands[ J]. ASCE, Journal of Structural Engineers, 2007, 133 ( 11 ) : 1627 - 1635.
  • 8Cao L, Naito C. Precast Concrete Double-tee Connections, part 2: Shear Behavior[J]. PCI Journal, 2009(2) : 97 -115.
  • 9Pincheira J A, Oliva M G, W Zheng. Behavior of Double-Tee Flange Connectors Subjected to In-Plane Monotonic and Reversed Cyclic Loads[J]. PCI Journal, 2005 (6): 2-24.
  • 10American Concrete Institute (ACI) Committee 318. Building Code Requirements for Structural Concrete ( ACI318 - 05 ) and Commentary[ S]. Farmington Hills, MI: ACI. 2005.

共引文献148

同被引文献16

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部