期刊文献+

核电厂排污系统中磁棒吸附对放射性探测的影响

Influence of Magnetic Rod Adsorption on Radioactive Detection in Nuclear Power Plant Steam Generator Blow Down System
下载PDF
导出
摘要 在研制核取样系统(REN)专用过滤装置过程中,考虑引入磁性过滤技术。本文研究了磁棒吸附对核电厂不同运行工况下的主要特征核素的测量影响,比较了磁棒在静置和搅拌模式下对放射性核素的吸附效率。结果表明,磁棒吸附对放射性测量的影响与放射性核素、存在的形态及核素活度浓度有关,不受样水流动的影响,在蒸汽发生器排污系统取样管线增加磁性过滤装置具有可行性。 In the process of developing a special filtration device for nuclear sampling system ( REN ), the magnetic filter technology was introduced. The influence of magnetic rod adsorption on the main characteristic nuclide measurement was studied under different operating conditions, and the radionuclide adsorption efficiency of the magnetic rod was compared in static and stirring mode. The results show that the influence of magnetic rod adsorption on radioactivity measurement is related to the radionuclides, the existing form and the nuclide activity concentration, and is not affected by the flow of the sample water. It is feasible to add the magnetic filter device in the sampling line of the steam generator sewage system.
作者 雷水雄 韩玉刚 邹世伟 蒲代伟 张庆亮 LEI Shui-xiong;HAN Yu-gang;ZOU Shi-wei;PU Dai-wei;ZHANG Qing-liang(CNNP Nuclear Operations Management Co Ltd,Haiyan Zhejiang 314300,China)
出处 《核电子学与探测技术》 CAS 北大核心 2019年第2期217-221,共5页 Nuclear Electronics & Detection Technology
关键词 磁棒 吸附 放射性核素 测量 活度浓度 magnetic rod adsorption radionuclide measurement activity concentration
  • 相关文献

参考文献2

二级参考文献3

  • 1广东核电培训中心.900MW压水堆核电站系统与设备[M].北京:原子能出版社,2004.
  • 2ASTM D6301-2013,Standard Practice for Collection of On-Line Composite Samples of Suspended Solids and Ionic Solids in Process Water[S].2013.
  • 3DLT502-2006,火力发电厂水汽分析方法[S].2006.

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部