期刊文献+

基于图像质量评估的医院超声诊断仪报废申请评价方法研究 被引量:6

Research on Evaluation Method of Scrapping Application for Hospital Ultrasonic Diagnostic Equipment Based on Image Quality Assessment
下载PDF
导出
摘要 医用超声诊断仪一直重视前期采购和中期管理,后期的设备报废往往被忽视。结合医院现有医疗设备报废程序和报废管理制度,思考更加合理的医院超声诊断仪的报废申请评价方法。本研究基于图像质量评估,从设备运行状况、图像质量检测、临床应用等三个层面评价超声诊断仪的报废申请。评估结果包含定性、定量参数检查,权重计算分值。同时发散思维创新报废评价方式,使医疗设备的报废决策更多元化,弥补医院超声诊断仪报废申请评价方法的不足,为新设备的采购提供辅助建议。 Medical ultrasound diagnostic equipment has been focused on early procurement and mid-term management,and late equipment scrapping is often overlooked.To consider more reasonable ways to evaluate the application for scrapping hospital ultrasound diagnostic equipment combined with the hospital's existing medical equipment end-of-life procedures and end-of-life management system.Based on image quality assessment,this study evaluated the application for scrapping ultrasonic diagnostic equipment from three levels:equipment operation status,image quality detection,and clinical application.The evaluation results included qualitative and quantitative parameter checking,and weights were calculated.At the same time,divergent thinking and innovative end-of-life evaluation methods can make the medical equipment's scrapping decision more diversified,make up for the shortage of hospital ultrasonic diagnostic apparatus scrapping application evaluation methods,and provide supplementary suggestions for the procurement of new equipment.
作者 张晓峰 路鹤晴 严浩 ZHANG Xiaofeng;LU Heqing;YAN Hao(Department of Medical Equipment,Shanghai First Maternity and Infant Hospital,Tongji University,Shanghai 201204,China)
出处 《中国医疗设备》 2019年第8期138-141,共4页 China Medical Devices
关键词 图像质量评估 超声诊断仪 质量控制检测 报废评估 image quality assessment ultrasound diagnostic apparatus quality control testing scrap assessment
  • 相关文献

参考文献14

二级参考文献54

共引文献80

同被引文献61

引证文献6

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部