期刊文献+

预应力钢筒混凝土管断丝检测数值仿真等效模型

Equivalent Model of Prestressed Concrete Cylinder Pipe Wire Breakage Detection Based on Finite Element Method
下载PDF
导出
摘要 有限元仿真常用于辅助分析预应力钢筒混凝土管断丝检测数据,在建模过程常遇到预应力钢丝螺旋结构网格划分困难,单元数量过多的情况。将预应力钢丝的螺旋结构模型等效成圆环模型以简化建模。针对含有阴极保护钢带的E型管道,对比分析了螺旋线结构+两条钢带模型、圆环+两条钢带模型和无钢带圆环模型的计算结果;针对L型管道,考虑了断丝时钢丝与钢筒之间脱开的效应。计算结果表明,对于含有阴极保护钢带的E型管道,圆环+两条钢带的模型与螺旋线模型等效效果最好,无钢带圆环模型等效效果较差;对于L型管道,圆环模型断口间距与螺旋线模型中钢丝与钢筒脱开的环向距离一致时,圆环模型和螺旋线模型等效。 Finite element method is often used for the assistant analyses of the broken wire inspection data from prestressed concrete cylinder pipes. It is usually difficult to discretize mesh for the spiral model of the prestressed wires,which always results in too many elements for analysis. The spiral structure was used to be equivalent to the separate round rings for simplicity. As for the embedded type of pipe with shorting straps,the spiral model are compared with two straps,ring model with two straps,ring model without straps. As for lined type of pipes,the effect of the disconnection between wires and the cylinder were discussed. The analyses results imply that for the embedded type of pipe with shorting straps,the ring model with two straps has the best equivalent effect while the ring model without straps is the worst. For the lined type of pipe,the spiral structure can only be equivalent as the ring model,in which the fracture distance has to be set as the circumferential distance of disconnection between wires and the cylinder.
作者 王正 董猛 商峰 王海超 WANG Zheng;DONG Meng;SHANG Feng;WANG Hai-chao(School of Civil Engineering and Architecture,Shandong University of Science and Technology,Qingdao 266590,China;Research Centcc for Sustainable Hydropower Development,China Institute of Water Resources and Hydropower Research,Beijing 100038,China)
出处 《科学技术与工程》 北大核心 2019年第20期115-121,共7页 Science Technology and Engineering
基金 国家重点研发计划(2018YFC0406903) 中国水利水电科学研究院科研专项(SS0145B122017)资助
关键词 预应力钢筒混凝土管 断丝检测 有限元 钢带 prestressed concrete cylinder pipe broken wire inspection finite element method straps
  • 相关文献

参考文献2

二级参考文献14

  • 1林鹤云,孙雨施,曲民兴.远场涡流三维缺损检测机理的有限元分析[J].南京航空学院学报,1993,25(1):18-27. 被引量:3
  • 2GB/T21448-2008,埋地钢质管道阴极保护技术规范[S].
  • 3GB50487-2008,水利水电工程地质勘察规范[S].
  • 4岩土工程勘察规范(2009年版)GB50021-2001[S].2009(10).
  • 5吴荫顺,李久青,曹备,等译.腐蚀工程手册[M].北京:中国石化出版社,2003.
  • 6GB50646-2008.工业建筑防腐蚀设计规范[S].
  • 7NACE RP0100-2004. Cathodic Protection of Pres- tressed Concrete Cylinder Pipeline[S].
  • 8C-B/T214472008.钢质管道外腐蚀控制规范[S].
  • 9臧晗宇,孙国涛.预应力钢管混凝土管道的阴极保护测量组元[P].中国:201120056714.6,2011.
  • 10GB/T19685-2005,预应力钢筒混凝土管[S].中国国家标准化管理委员会.

共引文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部