摘要
为了解决机组运行中轴加风机定期切换时经常发生过载跳闸、轴加风机电机烧损的状况,对比多个电厂系统结构,分析跳闸的原因,经过简单的改造后,运行12个月,结果表明该改造方案经济实惠,隐患彻底消除。
In order to solve the problem of overload tripping and burning of fan-fed motor during the periodic switching of fan-fed shaft in unit operation. By comparing the system structures of several power plants, the reasons for tripping are analyzed. After simple modification, the system runs for 12 months. The results show that the system is economical and practical, and the hidden dangers are completely eliminated.
作者
张永富
Zhang Yongfu(Power Generation Department of Jiangsu Kanshan Power Generation Co.,Ltd.,XuzhouJiangsu 221134)
出处
《现代工业经济和信息化》
2019年第7期123-125,共3页
Modern Industrial Economy and Informationization
关键词
轴加风机
定期切换
电机烧损
shaft plus fan
periodic switching
motor burnout