摘要
本文介绍了某联合循环电厂在联合循环启停过程NOX时均值超标的原因,提出了相应改进方法,为同类型电厂运行提供参考。
This paper introduces the reasons why the NOX mean value of a combined cycle power plant exceeds the standard in the start-up and shutdown process of the combined cycle,and puts forward the corresponding improvement methods,which can provide reference for the operation of the same type of power plant.
出处
《电力系统装备》
2019年第13期102-103,共2页
Electric Power System Equipment
关键词
贫-贫模式
进气加热系统
时均值
缸温变化率
poor-poor mode
intake heating system
time average
cylinder temperature change rate