期刊文献+

不同湿法脱硫工艺对燃煤电厂PM2.5排放的影响 被引量:11

Effect of a Wet Flue Gas Desulphurization System on the Emission of PM2.5 from Coal-Fired Power Plants
原文传递
导出
摘要 湿法脱硫系统被广泛应用于火电厂脱除烟气中的SO2,一方面对烟气中的PM2.5有一定的去除作用,但同时也会产生新的颗粒物,其净效应近年来受到广泛关注.选择3台装有不同湿法脱硫工艺的燃煤机组(石灰石-石膏单塔脱硫、石灰石-石膏双塔串联脱硫以及海水脱硫),采集了脱硫系统入口和出口的PM2.5样品,分析了PM2.5的质量浓度和元素组成.根据PM2.5化学组分物质守恒建议了一种估算脱硫塔对PM2.5去除率和增加率的方法,可选择Ti、Pb、Cr和V等元素作为参照.结果表明,所测试的3种湿法脱硫系统对PM2.5的去除率较为一致(67. 5%~84. 4%),平均为77. 1%,但增加率差别较大.其中,石灰石-石膏双塔串联系统的PM2.5增加率较低,仅为8. 6%,主要是由于二级吸收塔入口烟气温度降低,脱硫浆液液滴蒸发减弱导致携带减少;海水脱硫系统PM2.5增加率为23. 9%,这可能与脱硫海水不循环从而所含固体浓度较低有关;而石灰石-石膏单塔脱硫系统可能由于除雾器运行效率较差导致PM2.5增加率高达162. 3%. Wet flue gas desulphurization (WFGD) is wildly used to control SO2 emission from coal-fired power plants. The influence of WFGD on particulate matter (PM) emission has recently drawn significant public attentions in China.In this study, PM2.5 was collected at both the inlet and outlet from three WFGD units, including a single scrubber lime-stone-gypsum FGD unit, a cascade scrubber lime-stone-gypsum FGD unit, and a seawater FGD unit. PM2.5 mass concentrations and their chemical compositions were analyzed. A method to calculate the addition and removal ratios is proposed according to the concertation of PM2.5 components, such as Ti, Pb, Cr, and V. The results indicate that the removal ratio was similar between the three WFGD units (77.1% on average). However, the addition ratio varied significantly. The performance of the cascade scrubber lime-stone-gypsum FGD unit was best, with a lower addition ratio of 8.6%, which is attributed to the weaker evaporation of desulphurization slurry droplets in their second tower under the low temperature of the flue gas. The addition ratio of the seawater FGD unit was also low (23.9%) because of its low concentration of solids in the seawater. The addition ratio of the single scrubber lime-stone-gypsum FGD system was highest, with a value of 162.3%, which was probably due to the low efficiency of the de-mister.
作者 邓建国 马子轸 李振 段雷 蒋靖坤 DENG Jian-guo;MA Zi-zhen;LI Zhen;DUAN Lei;JIANG Jing-kun(School of Environment,Tsinghua University,Beijing 100084,China;State Environmental Protection Key Laboratory of Sources and Control of Air Pollution Complex,Beijing 100084,China)
出处 《环境科学》 EI CAS CSCD 北大核心 2019年第8期3457-3462,共6页 Environmental Science
基金 国家重点研发计划项目(2018YFC0213202)
关键词 固定源 脱硫塔(FGD) 脱硫浆液携带 可过滤PM2.5 元素 烟尘 stationary source flue gas desulphurization (FGD) entrainment of desulphurization slurry filterable PM2.5 element dust
  • 相关文献

参考文献7

二级参考文献86

共引文献183

同被引文献138

引证文献11

二级引证文献52

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部