摘要 目的为了进一步监管电磁辐射对环境的影响,对新疆部分地区做了电磁辐射评价。方法选取新疆维吾尔自治区已经建成的110、220和750 kV变电站及输电线路,跟据HJ 681-2013《交流输变电工程电磁环境监测方法》的要求,分别监测其距地面高1.5 m处的电场、磁感应强度。结果电场和磁感应强度测量结果的最高值为110 kV输变电工程变电站292 V/m、1.397μT。输电线路1 282.6 V/m、0.085μT;220 kV输变工程变电站1 784 V/m、2.506μT,输电线路1 507 V/m、0.567μT;750 kV输变电工程变电站1 144.88 V/m、0.422μT,输电线路5 952.4 V/m、2.523μT。结论监测结果表明新疆地区不同高压输变电工程的电磁辐射水平符合国家环境电磁波卫生标准。 Objective To further monitor the impact of electromagnetic radiation on the environment,conduct electromagnetic radiation evaluation in some areas of Xinjiang. Methods The established 110,220 and 750 kV power transformer and transmission lines in Xinjiang Uygur Autonomous Region were selected,to detect the intensity of electric fields and magnetic fields from the ground height 1.5 m respectively according to the requirements of the Electromagnetic environmental monitoring method of AC transmission and transformation project(HJ 681-2013). Results The maximum measurement values of electric fields and magnetic fields were as follows:292 V/m and 1.397 μT for substation,1 282.6 V/m and 0.085 μT(110 kV) for transmission line,1 784 V/m and 2.506 μT for substation,1 507 V/m and 0.567 μT(220 kV) for transmission line,1 144.88 V/m and 0.422 μT for substation,5 952.4 V/m and 2.523 μT(750 kV) for transmission line. Conclusion The results show that the electromagnetic radiation level of different high voltage lines in Xinjiang region is in good agreement with the health standard of national environmental electromagnetic wave radiation.
作者 麦麦提吐逊·玉素甫 王志煌 买买提热夏提·买买提 赵其文 Maimaitituxun·Yusufu;WANG Zhi-huang;Mamatrishat Mamat;ZHAO Qi-wen(School of Physics and technology,Xinjiang University,Urumqi Xinjiang,830046,China;Electromagnetic Chamber,Xinjiang Radiation Environment Supervision Station,Urumqi Xinjiang,830000,China)
出处 《职业与健康》 CAS 2019年第14期1979-1984,共6页 Occupation and Health
关键词 电磁辐射 高压输电线 变电站 Electromagnetic radiation High-voltage power lines Substations
  • 相关文献

参考文献6

二级参考文献55

共引文献51

同被引文献31

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部