期刊文献+

75Cr1锯片断裂失效分析 被引量:1

Failure Analysis of 75Cr1 Saw Blade
下载PDF
导出
摘要 采用通道式合金分析仪、光学显微镜、拉伸试验机、洛氏硬度仪、扫描电子显微镜观察分析了锯片的化学成分、微观组织、力学性能和洛氏硬度以及断口宏观和微观形貌,并结合锯片开裂现场工况条件进行了失效分析。结果表明:该锯片的断裂是由于锯片使用时失稳和生产时不当的热处理工艺等因素所导致。 The chemical composition, microstructure, mechanical properties, Rockwell hardness and fracture morphology of the saw blade were observed and analyzed by means of channel alloy analyzer, optical microscope, tensile tester, Rockwell hardness tester and scanning electron microscope. Failure analysis was carried out under the condition of saw blade cracking on site.The results show that, the fracture of the saw blade is caused by the instability of the saw blade during using and the improper heat treatment process.
作者 刘杰 程东岳 洪亮 周华 LIU Jie;CHENG Dongyue;HONG Liang;ZHOU Hua(Zhejiang Special Equipment Inspection and Research Institute, Hangzhou 310020, China;Key Laboratory of Special Equipment Safety Testing Technology of Zhejiang Province, Hangzhou 310020, China;Hangzhou Jigang Tools Co., Ltd.,Hangzhou 310020, China)
出处 《热加工工艺》 北大核心 2019年第14期178-180,共3页 Hot Working Technology
基金 浙江省质检系统科研计划项目(20180109)
关键词 75Cr1 锯片 失效分析 75Cr1 saw blade failure analysis